Precautions for decoration approach protection
裝修進(jìn)場保護(hù)注意事項(xiàng)
2 防塵保護(hù)
通風(fēng)管道保護(hù)
風(fēng)口防塵保護(hù)
裝修前應(yīng)對智能集控器、智能檢測器、環(huán)境一體機(jī)等采取防塵保護(hù)措施,
以免造成精密電子元器件污染和損壞,如有污損將會導(dǎo)致室內(nèi)各項(xiàng)數(shù)據(jù)
指標(biāo)檢測異常、指令無法傳輸或傳輸錯誤,影響設(shè)備正常運(yùn)行。
裝修前應(yīng)對通風(fēng)管道進(jìn)行保護(hù),嚴(yán)禁拆改磕碰風(fēng)管,拆改磕碰風(fēng)管將
導(dǎo)致室內(nèi)氣流組織混亂、冷熱不均、風(fēng)量不均、無法達(dá)到健康舒適的
居住效果,甚至?xí)?dǎo)致綠色智慧健康建筑集成系統(tǒng)失效。
裝修前應(yīng)對各方間內(nèi)的風(fēng)口進(jìn)行防塵保護(hù),防止裝修灰塵從風(fēng)口進(jìn)入
室內(nèi)管道;如管道內(nèi)有積塵,開機(jī)后會隨著新風(fēng)吹入室內(nèi),導(dǎo)致室內(nèi)
二次污染。
裝修進(jìn)場保護(hù)注意事項(xiàng)
3
環(huán)境一體機(jī)
接水盤
冷凝水排水管
接水盤
冷凝水排水管
嚴(yán)禁破壞、磕碰冷凝水
排水管以防導(dǎo)致接水盤
的邊緣破裂漏水
環(huán)境一體機(jī)冷媒管、保溫套管保護(hù)
環(huán)境一體機(jī)冷凝水排水管、保溫套管保護(hù)
冷凝水排水管標(biāo)高保護(hù)
嚴(yán)禁破壞環(huán)境一體機(jī)冷媒管及其保溫套管,如不慎破壞將出現(xiàn)冷媒管凝
露滴水、冷媒泄漏、冬季室內(nèi)溫度不升、夏季室內(nèi)溫度不降、能耗升高
且無法達(dá)到健康舒適居住效果。
嚴(yán)禁破壞環(huán)境一體機(jī)冷凝水排水管及其保溫套管,如不慎破壞將導(dǎo)致
冷凝水跑冒滴漏、損毀設(shè)備、污染吊頂?shù)取?/p>
嚴(yán)禁裝修過程中為貼磚或吊頂?shù)忍Ц呃淠潘軜?biāo)高、破壞排水坡
度,出現(xiàn)冷凝水倒流的情況。
Note for demolition and modification
嚴(yán)禁拆改注意事項(xiàng)
6 嚴(yán)禁拆除注意事項(xiàng)
01
02
嚴(yán)禁在所有外墻、分戶墻、樓地面、屋面、露臺等原有結(jié)構(gòu)上進(jìn)行鉆孔、
打洞、穿管、剔鑿、改造、加建其他設(shè)施等,以免破壞保溫層和氣密層,
產(chǎn)生熱橋效應(yīng),甚至導(dǎo)致綠色智慧健康建筑集成系統(tǒng)失效。
嚴(yán)禁拆改或封閉陽臺,綠色智慧健康建筑集成系統(tǒng)的設(shè)計需要經(jīng)過嚴(yán)密
的數(shù)據(jù)計算和運(yùn)行模擬,如果擅自改造將嚴(yán)重破壞設(shè)計效果、增加能耗,
無法達(dá)到健康舒適的居住效果。內(nèi)飾面層 基層墻體 保溫層 外飾面層
保溫層
耐堿網(wǎng)格布
防水隔汽膜
03
嚴(yán)禁拆改移位被動式入戶門和 外窗,嚴(yán)禁破壞門窗四周防水隔汽膜和防
水透氣膜等氣密措施,如拆改破壞將導(dǎo)致能耗升高且綠色智慧健康建筑
集成系統(tǒng)完全失效,無法達(dá)到健康舒適的居住效果。
防水透氣膜
7
04
嚴(yán)禁拆改遮陽及配套掛件,遮陽具有防曬、隔聲、保溫等性能,如拆改
破壞不僅會導(dǎo)致使用功能缺失,更會在拆改的過程中破壞建筑物的氣密
系統(tǒng),甚至可導(dǎo)致綠色智慧健康建筑集成系統(tǒng)失效;如果建筑配有戶外
太陽能光伏板或其他設(shè)施,同樣嚴(yán)禁拆改。
太陽能板
入戶門
遮陽系統(tǒng)
被動窗
電線
線管封堵示意圖
密封材料線管 強(qiáng)弱電箱
氣密性封堵
氣密性封堵
05
嚴(yán)禁對公共配電設(shè)施、通訊設(shè)施、給排水管、戶內(nèi)強(qiáng)弱電箱、入戶電源
線等施工節(jié)點(diǎn)進(jìn)行拆改移位,因綠色智慧健康建筑集成系統(tǒng)的所有施工
節(jié)點(diǎn)都經(jīng)過氣密性和防熱橋處理,如果隨意破壞將導(dǎo)致建筑氣密性降低、
產(chǎn)生熱傳導(dǎo)現(xiàn)象,進(jìn)而導(dǎo)致能耗升高、甚至綠色智慧健康建筑集成系統(tǒng)
失效。如果必須改動,應(yīng)減少改動范圍并在專業(yè)人員的指導(dǎo)下進(jìn)行,改
動完畢后必須進(jìn)行專業(yè)的氣密性封堵和防熱橋處理。
8
08
09
06
07
嚴(yán)禁將雙層百葉可調(diào)節(jié)風(fēng)口更換為裝飾型風(fēng)口,以免影響導(dǎo)風(fēng)效果、打
亂送風(fēng)方向。
室內(nèi)各房間門與地板之間應(yīng)留有 20mm 以上縫隙作為溢流口,保障整
屋的空氣循環(huán)流通。
嚴(yán)禁拆改風(fēng)口位置或改變風(fēng)口尺寸,以免出現(xiàn)風(fēng)口與管道錯位、風(fēng)量不
足、憋風(fēng)或無法送風(fēng)等情況,達(dá)不到設(shè)計效果。
管道與風(fēng)口應(yīng)使用帆布軟連接,嚴(yán)禁使用鋁箔連接,以防風(fēng)口處產(chǎn)生冷
凝水。
裝飾性風(fēng)口導(dǎo)風(fēng)不穩(wěn)定 雙百葉風(fēng)口導(dǎo)風(fēng)穩(wěn)定
20mm
室內(nèi)門與地板間留有20mm
以上縫隙作為溢流口
裝飾型風(fēng)口導(dǎo)風(fēng)不穩(wěn)定 雙層百葉風(fēng)口導(dǎo)風(fēng)穩(wěn)定
Matters needing attention in ceiling
construction
吊頂施工注意事項(xiàng)
10 房間吊頂
洞口與風(fēng)管間留有
150mm—300mm
吊頂 木龍骨
風(fēng)管
雙層百葉
可調(diào)節(jié)風(fēng)口
帆布軟連接
洞口與風(fēng)管間留有
150mm—300mm
軟連接安裝距離
風(fēng)管
木龍骨
帆布軟連接
風(fēng)管
樓 板
風(fēng) 道
百葉送風(fēng)口
石膏板吊頂
樓 板
風(fēng) 道
百葉送風(fēng)口
石膏板吊頂
燈槽過寬
<200mm
燈槽過高
01
02
為風(fēng)口預(yù)留的吊頂洞口尺寸應(yīng)略大于風(fēng)口尺寸,四周架設(shè)木龍骨,百葉
風(fēng)口與風(fēng)管之間應(yīng)預(yù)留 150mm-300mm 軟連接安裝距離,軟連接應(yīng)為
帆布材質(zhì)且必須完全撐開,避免因帆布堵塞風(fēng)口影響送風(fēng)、回風(fēng)效果。
送風(fēng)口下方吊頂燈槽不宜過寬、燈槽立板不宜過高,以免遮擋送風(fēng)通道、
影響送風(fēng)效果,導(dǎo)致室內(nèi)達(dá)不到健康舒適的溫度。
11
設(shè)備間吊頂
01
02
宜選用蜂窩鋁板或石膏板等隔聲效果較好的吊頂材料,不建議選用小塊
單層薄金屬吊頂材料,以免產(chǎn)生共振且擴(kuò)音傳聲,同時禁止吊頂龍骨遮
擋環(huán)境一體機(jī)門板,以免影響日常檢修養(yǎng)護(hù)。
應(yīng)對吊頂內(nèi)采取隔聲降噪吸音等處理措施,常用方式是在吊頂空間內(nèi)進(jìn)
行六面滿貼厚度≥ 50mm 的蛋殼吸音棉,并確保每一面粘貼吸音棉后
與環(huán)境一體機(jī)仍有一定空間距離。(如果不考慮成本因素,可以選用級
別更高的隔音材料或隔音措施)
吸音材料
蜂窩鋁板或石膏板吊頂
有電動風(fēng)閥
≥100mm
≥100mm
≥100mm
≥100mm
保證設(shè)備電控箱處
留有≥200mm的維
修操作空間
檢修口示意圖(有電動風(fēng)閥)
12 03
環(huán)境一體機(jī)正下方應(yīng)按照示意圖標(biāo)識尺寸預(yù)留檢修口(檢修口也應(yīng)進(jìn)
行隔音處理),保證環(huán)境一體機(jī)門板可以完全打開且側(cè)邊的電控箱
有足夠的檢修操作空間,如果環(huán)境一體機(jī)門板與吊頂之間垂直距離
≥ 300mm,電控箱側(cè)檢修操作空間應(yīng)增加 100mm 以上。
100mm
100mm 100mm
100mm
電動風(fēng)閥
有電動風(fēng)閥
≥100mm
無電動風(fēng)閥
≥100mm ≥100mm
≥200mm 保證設(shè)備電控箱處
留有≥200mm的
維修操作空間
檢修口示意圖(無電動風(fēng)閥)
電動風(fēng)閥
13
04
05
管道上安裝的電動風(fēng)閥、手動風(fēng)閥、防凍保護(hù)箱等位置應(yīng)按照示意圖標(biāo)
注尺寸預(yù)留檢修口,便于調(diào)試和檢修。
嚴(yán)禁將吊卡、吊桿、吊頂龍骨等各種裝修配套件與環(huán)境一體機(jī)、管道、
吊筋等相關(guān)部件接觸或共用,以免共振傳聲或加重荷載。
50mm 50mm
100mm
50mm
手動風(fēng)閥
50mm
50mm
50mm
50mm
防凍保護(hù)箱
防凍保護(hù)箱
手動風(fēng)閥
14
Precautions for kitchen and sanitary construction
廚衛(wèi)施工注意事項(xiàng)
16 廚衛(wèi)施工注意事項(xiàng)
氣密性良好
的煙道止回閥
廚房吊頂
煙機(jī)安裝
廚房補(bǔ)風(fēng)
選用煙機(jī)時,應(yīng)型號適當(dāng),排風(fēng)量不易過大,防止室內(nèi)煙機(jī)排風(fēng)與補(bǔ)風(fēng)
失衡;安裝煙機(jī)時,應(yīng)使用預(yù)留排煙孔洞,嚴(yán)禁自行在煙道上開孔,以
免破壞煙道氣密性,同時應(yīng)安裝氣密性良好的煙道止回閥并做好密封處
理,避免出現(xiàn)廚房串味。
為防止室內(nèi)出現(xiàn)負(fù)壓現(xiàn)象,保障煙機(jī)排風(fēng)與補(bǔ)風(fēng)平衡,煙機(jī)開啟時應(yīng)同
步打開廚房補(bǔ)風(fēng)裝置;廚房補(bǔ)風(fēng)裝置不宜遮擋,如需安裝櫥柜應(yīng)選用百
葉柜門,保障補(bǔ)風(fēng)效果。
17
廚衛(wèi)排水
環(huán)境一體機(jī)回風(fēng)口
地漏
廚 房 洗 菜 盆 和 衛(wèi) 生 間 洗 漱 池 等 排 水 管 道 應(yīng) 設(shè) 置 存 水 彎, 水 封 深 度
≥ 50mm,且排水管道與房屋排水系統(tǒng)連接部位應(yīng)做好密封處理,防止
污濁氣體向室內(nèi)倒灌。
環(huán)境一體機(jī)的回風(fēng)多設(shè)置于衛(wèi)生間內(nèi),回風(fēng)口應(yīng)單獨(dú)預(yù)留,嚴(yán)禁與浴霸
的排風(fēng)系統(tǒng)或排風(fēng)扇共用,且風(fēng)口與風(fēng)管間應(yīng)安裝軟連接。
嚴(yán)禁選用機(jī)械密封型地漏,宜選用水封型地漏,對不經(jīng)常使用的水封型
地漏定期補(bǔ)水,確保水封持續(xù)發(fā)揮作用,防止污濁氣體向室內(nèi)倒灌。
回風(fēng)口
水封型地漏
水封型地漏
機(jī)械密封
型地漏
軟連接
新風(fēng)系統(tǒng)回風(fēng)管
19
Contact Lowcarn
聯(lián)系洛卡恩
服務(wù)時間:
全年 365 天 每天 24 小時 節(jié)假無休
聯(lián)系我們:
服務(wù)熱線:400-1108-678
工程師專線:0312-5590966
官方網(wǎng)站:WWW.LOWCARN.COM
企業(yè)名稱:
奧潤順達(dá)集團(tuán)
河北綠色建筑科技有限公司
Precautions for Protection upon Entering the
Decoration Site
Dust proof protection
Vent duct protection
Air outlet for dust proof protection
Environment integrated machine refrigerant pipe and thermal insulation
pipe protection
Environment integrated machine condensing water drainage pipe and
thermal insulation pipe protection
Condensate water drainage pipe elevation protection
Note for demolition and modification
Note for ceiling construction
Room celling
Ceiling construction in the equipment room
26
26
27
27
26
27
30
34
35
Precautions for kitchen and sanitary construction
Kitchen ventilator installation
The kitchen wind supplement
Kitchen and bathroom drainage
The return air of the environment all-in-one machine
Floor drain
Lowcarn10 full service
Contact Lowcarn
40
41
41
40
41
43
45
Precautions for Protection upon
Entering the Decoration Site
24 Dust proof protection
Vent duct protection
Air outlet for dust protection
Before decoration, dust proof protection measures should be taken for
intelligent controller, intelligent detector and environmental all in-one machine
to avoid pollution and damage of precision electronic components. If there is
dirt, it will lead to abnormal detection of indoor data indicators, instructions
cannot be conveyed or transfer error, then it will effect the normal operation.
Before decoration, the ventilation pipe should be protected, and it is strictly
prohibited to dismantle and bump against the air duct. Demolition and bump
against the air duct will lead to indoor air flow disorder, uneven cold and heat,
uneven air volume, unable to achieve healthy and comfortable living effect, and
even lead to theinvalidity of the ultra low energy comsumption.
Before decoration, the air outlet in all parties shall be protected to prevent the
decoration dust from entering the indoor pipe from the air outlet; if there is
dust in the pipe, it will blow into the room with the fresh air, leading to indoor
secondary pollution.
Precautions for Protection upon Entering the
Decoration Site
25
Environmental all-inone machine
defrosting tray
Condensate drain pipe
defrosting tray
Condensate water drain pipe
Do not damage, knock against the
cold Condensate water drain pipe to
prevent the water tray from cracking
and leaking
Environmental integrated machine refrigerant tube
and insulation casing protection
Environment integrated machine condensing
water drainage pipe, protection casing protection
Condensate water drainage, pipe elevation
protection
It is strictly prohibited to destroy the refrigerant tube of the environmental
integrated machine and its insulation casing. If accidentally damaged, the
refrigerant tube will condense water, refrigerant leakage, indoor temperature
will not rise in winter, indoor temperature does not fall in summer, energy
consumption will increase and the ideal living effect cannot be achieved.
It is strictly prohibited to destroy the condensate drainage pipe and its insulation
casing of the environmental all-in-one machine. If damaged carelessly, it will
lead to condensate water leakage, damage to equipment, polluted ceiling, etc.
It is strictly prohibited to raise the elevation of the condensed water drainage
pipe in the decoration process of brick or ceiling, destroy the drainage slope,and
reverse the condensed water.
Note for demolition and
modification
28 No removal, matters needing attention
01
02
It is strictly prohibited to drill, hole, pipe, dig, transform andbuild other facilities
on all original structures such as externalwalls, household walls, floors, roofs
and terraces, so as not todamage the insulation layer and air tight layer, produce
heatbridge effect, and even lead to the failure of Lowcarn green smart and
healthy building.
It is strictly forbidden to dismantle, change or close the balcony. The design of
the green smart and healthy building needs to be strictly Dense data calculation
and operation simulation.If change arbitrarily will seriously damage the design
effect and increase energy Consumption, unable to achieve a healthy and
comfortable living effect.
External surface layer Insulation Base wall Interior surface layer
Insulation
alkali resistant mesh cloth
03
It is strictly prohibited to remove or move the passive door and passive outer
window, and it is strictly prohibited to destroy the air tightness measures such
as waterproof and waterproof breathable around the doors and Windows. If
the system is damaged, it will cause the increased energy consumption and the
complete failure of the passive ultra-low energy consumption building, which
cannot achieve a healthy and comfortable living effect.
Waterproof breathable
membrane
waterproof non breathable
membrane
29
It is strictly prohibited to dismantle or modify sunshades and supporting
accessories. Sunshades have properties such as sun protection, sound
insulation, and heat preservation. If they are dismantled or damaged, it will not
only lead to the loss of use functions, but also destroy the building's airtight
system in the process, and may even cause the green smart and healthy building
to fail; if the building is equipped with outdoor solar photovoltaic panels or other
facilities, it is also strictly prohibited to dismantle or modify them.
04
solar panel
The door
Sunshading system
Passive window
電線
線管封堵示意圖
密封材料線管 強(qiáng)弱電箱
氣密性封堵
氣密性封堵
05
It is strictly prohibited to dismantle, modify, or relocate construction nodes such
as public power distribution facilities, communication facilities, water supply
and drainage pipes, indoor strong and weak electrical boxes, and household
power lines. All construction nodes of green smart and healthy building have
undergone airtightness and thermal bridge treatment. If they are arbitrarily
damaged, it will lead to a decrease in building airtightness, heat conduction, and
ultimately increase energy consumption, and even the failure of green smart and
healthy building building. If it is necessary to make changes, the scope of the
changes should be reduced and carried out under the guidance of professional
personnel. After the changes are completed, professional airtight sealing and
anti thermal bridge treatment must be carried out.
30
08
09
06
07
There should be a gap of more than 20mm left between the door and the floor
of each room as an overflow port, so that the indoor fresh air and return air
balance, and ensure the air circulation of the whole room.
It is strictly prohibited to remove or change the position of the tuyere or change
the size of the tuyere, so as to avoid the dislocation between the tuyere and the
pipeline, insufficient air volume, holding back the wind or unable to supply the
air, and fail to achieve the design effect.
The pipe and the air outlet should be soft connected with canvas,and aluminum
foil is strictly prohibited to prevent condensate water at the air outlet.
裝飾性風(fēng)口導(dǎo)風(fēng)不穩(wěn)定 雙百葉風(fēng)口導(dǎo)風(fēng)穩(wěn)定
20mm
室內(nèi)門與地板間留有20mm
以上縫隙作為溢流口
It is strictly prohibited to replace the double-layer shutter adjustable tuyere
with decorative air tuyere, which affects the air guide effect and disrupts the air
supply direction.
Precautions for Ceiling
Construction
32 1、 Room ceiling
洞口與風(fēng)管間留有
150mm—300mm
吊頂 木龍骨
風(fēng)管
雙層百葉
可調(diào)節(jié)風(fēng)口
帆布軟連接
洞口與風(fēng)管間留有
150mm—300mm
軟連接安裝距離
風(fēng)管
木龍骨
帆布軟連接
風(fēng)管
樓 板
風(fēng) 道
百葉送風(fēng)口
石膏板吊頂
樓 板
風(fēng) 道
百葉送風(fēng)口
石膏板吊頂
燈槽過寬
<200mm
燈槽過高
01
02
The size of the ceiling opening reserved for the air outlet should be slightly larger
than the size of the air outlet. Wooden keels should be installed around it, and
a soft connection installation distance of 150mm-300mm should be reserved
between the louver air outlet and the air duct. The soft connection should be
made of canvas material and must be fully stretched to avoid affecting the air
supply and return effect due to canvas blocking the air outlet.
The ceiling light trough below the air supply outlet should not be too wide, and
the light trough vertical plate should not be too high, so as not to block the air
supply channel and affect the air supply effect, resulting in the indoor can to
reach a healthy and comfortable temperature.
33
Measures such as sound insulation, noise reduction and sound absorption
should be taken in the ceiling. The common way is to make six eggshell cotton
with a thickness of 50mm in the ceiling space, and ensure that there is still a
certain space distance with the environmental all-in-one machine.(If the cost
factor is not considered, you can choose a higher grade of sound insulation
materials or sound insulation measures)
2、 Ceiling construcion of the equipment room
01
02
It is advisable to choose honeycomb aluminum board or gypsum board and
other ceiling materials with good sound insulation effect, it is not recommended
to choose small single layer thin metal ceiling material, so as not to produce
resonance and amplification sound transmission, while prohibiting the ceiling
keel to block the environment integrated machine door board, so as not to affect
the daily maintenance and maintenance.
吸音材料
蜂窩鋁板或石膏板吊頂
有電動風(fēng)閥
≥100mm
≥100mm ≥100mm
≥100mm
保證設(shè)備電控箱處
留有≥200mm的維
修操作空間
34 03
A maintenance port should be reserved directly below the environmental
integrated machine according to the size indicated in the diagram (the
maintenance port should also be treated with sound insulation), ensuring that
the door panel of the environmental integrated machine can be fully opened
and there is sufficient maintenance operation space on the side of the electrical
control box. If the vertical distance between the door panel of the environmental
integrated machine and the ceiling is ≥ 300mm, the maintenance operation
space on the side of the electrical control box should be increased by more than
100mm.
100mm
100mm 100mm
100mm
電動風(fēng)閥
有電動風(fēng)閥
≥100mm
無電動風(fēng)閥
≥100mm ≥100mm
≥200mm 保證設(shè)備電控箱處
留有≥200mm的
維修操作空間
電動風(fēng)閥
35
05
It is strictly prohibited to lift the card, boom, ceiling keel and other decoration
accessories and environment integrated machine, pipe, Suspension bars and
other related parts contact or share, so as to avoid resonance sound transmission
or aggravating load.
50mm
50mm
50mm
50mm
防凍保護(hù)箱
04
It is strictly prohibited to lift the card, boom, ceiling keel and other decoration
accessories and environment integrated machine, pipe, Suspension bars and
other related parts contact or share, so as to avoid resonance sound transmission
or aggravating load.The electric air valve, manual air valve and anti-freezing
protection box installed on the pipeline should be marked according to the
schematic diagram, and the access port should be reserved for commissioning
and maintenance.
50mm 50mm
100mm
50mm
手動風(fēng)閥
防凍保護(hù)箱
手動風(fēng)閥
Precautions for kitchen
and sanitary construction
38 Kitchen and bathroom construction precautions
Smoke machine installation
The make-up air of kitchen
When selecting the smoke machine, the model should be appropriate and the
exhaust air volume should not be too large to prevent imbalance between indoor
air exhaust and makeup air. When installing a smoke exhaust fan,reserved smoke
exhaust holes should be used. It is strictly prohibited to open holes on the flue to
avoid damaging the airtightness of the flue. At the same time, a well sealed flue
check valve should be installed to avoid kitchen odor.
In order to prevent indoor negative pressure and ensure the balance betwee
air exhaust and air supply, the kitchen air repair device should be opened simultaneously; the kitchen air repair device should not be blocked, and cabinets
should be installed with Leaf cabinet door, to ensure the effect of wind repair.
氣密性良好
的煙道止回閥
廚房吊頂
39
Kitchen and bathroom drainage
The return air of the ventilation system is mostly
Floor drain
Kitchen washbasin and bathroom washbasin and other drainage pipes should be
set up with water storage bend, water seal depth ≥ 50mm, and the drainage pipe
and the house drainage system connection parts should be well sealed to prevent
foul gas to the indoor backflow.
The return air of the ventilation system is mostly set in the bathroom, and the
return air port should be reserved separately. It is strictly prohibited to share with
bathroom infrared heater exhaust system or exhaust fan, and a soft connection
should be installed between the air outlet and the air duct.
It is strictly prohibited to choose mechanical seal floor drain, it is appropriate to
choose water seal floor drain, for the irregularly used water seal floor drain to fill
water regularly, to ensure that the water seal can play a full role, to prevent the
dirty gas from pouring into the room.
Water-sealed ground leakage
Water-sealed ground
leakage
Mechan ical seale d type
floor drain
回風(fēng)口
軟連接
新風(fēng)系統(tǒng)回風(fēng)管
41
Contact Lowcarn
service time:
And 365 24 hours a day days in a whole year
contact us:
Service hotline:400-1108-678
Engineer's special line: 0312-5590966
Official website:WWW.LOWCARN.COM
enterprise name
ORIENT SUNDAR
Hebei Green Building Co., Ltd
43