Introduction Is a venture corporation and lies in Kaishi Industial D istrict zhangze,Yexie Town,Shanghai,China,it is an enterprise speci alizing in manufacture and sale of water pumps and obtains an ISO9001 certification. Our corporation has advanced equipment and great test center. Since our corporati on was established, ourproducts have been optimized and innova ted continually, they have the quality of imported poducts and the p ric e of pr odu ctsmade in our country. Our products have a comp... [收起]
[展開(kāi)]
凱仕KSWG型電子說(shuō)明書(shū)
粉絲: {{bookData.followerCount}}
文本內(nèi)容
第1頁(yè)

R

KSWG SERIES

KSWG Non-negative-pressure

(without suction lift) pipe network

pressure boosting stable current

water supply whole set equipment

第2頁(yè)

I

ntroduction

Is a venture

corporation and lies in Kaishi Industial D istrict zhangze,Yexie Town,Shanghai,China,it is an enterprise speci alizing in

manufacture and sale of water pumps and obtains an ISO9001

certification. Our corporation has advanced equipment and

great test center. Since our corporati on was established, our

products have been optimized and innova ted continually, they

have the quality of imported poducts and the p ric e of pr odu cts

made in our country. Our products have a complete range of

sizes and numerous varieties. Our corporation mainly produces,

equ ipm ent of water supply and drainage an interrelated electrical

controlling equipment etc. Our corporation is one of the

members of Chinese Environmental Protection Industrial

Association and Chinese Water Supply and Drainage Equipment

Association.

Now Kaishi has 570 staffs, 53 million assets and stands over

17.600 square-meters. Our corporstion has high technology,

flxible management system, 80 senior engineers and technology

administrative members and the solid foundation and rear

service to develop the high-tech production. Our corporation

can produce over 45,000 water pumps, the products are deeply

well received by the users from trades of environmental protection,

water supply a nd draina ge, chemical industry, metallurgy,

medicine, electrician and so on. Products are sold in more than

thirty provinces and cities of our country and exported to East

and South Asia, Korea, Indonesia, Russia and so on.

Kaishi people regard never-ending pursuit for best quality

as our creed, and produce exce llent p ump. We believe deeply

that our new and old customers and Kaishi tomorrow will be and

more splendid.

第3頁(yè)

1

1

223

( ) 4

( )5

( )6

7

8

9

10

10

11

Briefintroduction 1

Model & meaning 1

Mtechnical parameters 2

Working principle 2

Product features 3

Model selection of equipment (one for use and one for standby) 4

Model selection of equipment (two for use and one for standby) 5

Model selection of equipment (three for use and one for standby) 6

Instruction for model selection7

Use and maintenance of equipment 8

Installation and adjustment 9

Use and operation 10

Maintenance and servicing 10

Failures causes and troubleshooting 11

第4頁(yè)

KSWG (

) KSGP

!

1 ( )

( )

2 ( )

3

4

5 ( )

DL

KSWG ( )

( )

KAISHI Non-negative-pressure (without

suction lift) pipe network pressure boosting

stable current water supply whole set equipment

3 Capacity(m /h)

Head(m)

Quantity of water pump

Control cabinet system

Quantity of controlling water pump

Power of single set of controlling water pump

R

01

KSWG ( )

KSWG

KSWG non-negative-pressure (without suction lift) pipe network

pressure boosting stable current water supply whole set equipment

(hereinafter referred to as the equipment) is the new generation product

developed by our company on the basis of upgrading the original KSGP

frequency conversion constant pressure water supply series product.

According to the regulations in ules of Urban Water Supply it

is forbidden to directly install pump on urban public water supply pipes

to pump water! This is because that the negative pressure produced during

pumping will influence water use of other uses in the surroundings, or

even cause damage of pipes.

Therefore, during engineering design, the water pool or water tank

shall be firstly built. The urban water supply is put into the water pool

first and then is pressurized to the water supply pipe network of users.

In the case 1. Large investment. Cost for the building of water pool

(water tank), cost for installation of new water treatment equipment as

the water source in water pool is easily polluted an d cost of daily and

regular cleaning and sterilization of water pool (water tank)

shall be taken into consideration.

2. Water source is easily polluted. As the water pool (water tank) is

open, impurities, microbes and small animal bodies may easily pollute

the water source, especially in summer, the water is easily deteriorated

and smells off.

3. Waste of energy The pressure of urban p ipe network firstly

changes to zero and then start to pressurize from zero. The original

pressure is wasted and the model of pressure boosting pump is enhanced.

4. Waste of water source Water seepage, water running, water leakage

and evaporation may occur in the water pool. Moreover, regular rinsing

and sterilization costs labor and water.

5. High noise When the water level in the water pool (water tank)

descends due to water use, the large noise of water flow from tap water

and noise caused by operation of old style DL pump may exist.

The above problems can be thoroughly solved after adopting KSWG

non-negative-pressure (without suction lift) pipe network pressure

boosting stable current water supply whole set equipment produced by

our company.

KSKB KW

第5頁(yè)

3

1. 0~600m /h

2. 0~2.0MPa

3. <180kw

4. <0.01MPa

o

5. 0~+40 C

6. 90% ( )

7. 380Vx(1+10%)50Hz+2Hz

1

R

02

KSWG Non-negative-pressure (without suction lift) pipe network pressure

boosting stable current water supply whole set equipment

Pressure sensor

To user

Clean drainage valve

Stable current compensator

Preventer for return flow Filter

Butterfly valve

Negative

Connect tap water pressure gauge

Intelligent

frequency

conversion

control cabinet

System figure of non-negative-pressure (without suction lift) pipe network pressure boosting stable current water supply whole set equipment

3

1. Flow range: 0~600m /h

2. Pressure range: 0~2.0Mpa

3. Motor power of control pump: <180kw

4. Pressure regulating precision: <0.01Mpa

o

5. Environmental temperature: 0~+40 C

6. Relative temperature: under 90% (electric control part)

7. Power supply: 380Vx(1+10%)50Hz+2Hz

Butterfly valve

1. When the pressure of tap water is lower than the set pressure

required by user, the control system will automatically control the

frequency converter to start the operation through frequency conversion

soft starting until the actual working pressure of user pipe network is

equal to the set pressure. The frequency converter controls the frequency

conversion pump to operate at a constant rotation speed. The higher the

pressure of tap water is, the lower the rotation speed of frequency

conversion pump is, and vice versa. When the pressure of tap water

equals to the set pressure, the frequency conversion pump will delay the

time and sleep, which makes full use of the original pressure of tap water

to ensure that the pressure required by user is constant. When the pressure

drops to the awakening value, the water pump will be automatically

awakened.

第6頁(yè)

1 70

( 60M

30M )

2

3 20

4 70

70

5

6

7

8

( )

03

R

KSWG ( )

2

3

4

2. The water inlet of frequency conversion pump is connected with

the stainless steel stable current compensator, and the microcomputer is

always inspecting the pressure inside the stable current compensator.

Through the inspection to pressure of inlet water and automatic vacuum

suppresser, it is ensured that there is no negative pressure inside the

stable current compensator so as to guarantee the normal water supply

of tap water pipe network.

3. When tap water stops water supply, the equipment will automatically

stop. When the water supply is available, the equipment will automatically

start. In case of power cut, the normal pressure low area water supply

of tap water will automatically resume.

4. When producing instant negative pressure, please stop all power

frequency pumps first and then delay the time of frequency conversion

speed reduction without stopping the machine, which not only ensures

water use for user but also alleviates the condition of negative pressure.

1. Saving a total investment of 70%.

No need to build water pool or water tank. Directly connected with

the tap water pipe for pressure boosting water supply, which makes full

use of the original pressure of tap water and reduces model of water pump

(original water pump requires 60M lift, and the current one requires

only 30M.)

2. Water quality is pure

The pure tap water is directly supplied to user after pressure boosting

by the equipment. It is connected in sealed condition, which is absolutely

isolated from the air.

3. Saving water of 20%

Hermetic structure prevents the occurrence of running, dripping,

leakage and seepage, and the water wasted for regular cleaning and

sterilization. It is directly connected with tap water pipe.

4. Saving power of 70%

It makes full use of the original pressure of tap water pipe and

compensates the pressure amount that differs. When the tap water satisfies

the requirements, the equipment will stop its operation. The effect of

energy saving is so prominent that it can reach above 70%.

5. Saving space and installation time

No need to build water pool or install water tank with the whole set

equipment leaving the factory. After reaching the site, the water inlet

pipe and the water output pipe of tap water of user is directly connected

with the equipment with simple construction, short construction period

and small landing area.

6. Saving manpower and material resources

The water quality is not polluted through adopting the equipment.

No need to install sterilization equipment. Twice pollution is prevented.

The equipment is provided with small pressure stab ilizing tank, which

can further save the investment. As no water pool or water tank is requir ed,

the use is very economic that it saves the costs for regular cleaning and

sterilization.

7. Low noise

As the water pump is directly connected with tap water through

stable current compensator, there is no large noise of water flow from

tap water. The system adopts stainless steel light vertical multistage

centri fugal pump, which can gre atly reduce the noise caused by operation

of water pump.

8. Advanced control system

The equipment applies fuzzy control and integrated control etc.

world advanced control technology and is provided with powerful

remote supervising function and wireless supervising function (optional).

第7頁(yè)

No.

Type Head

(m)

Model of pressure

stabilizing tank

Stable current compensator

XL

3 M

Limited volume

Water pump (totaling 2 sets with

one for use and one for standby)

Type Power

User quantity

for reference

Model of frequency

conversion cabinet

kg

Approximate

weight

of equipment

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

19

20

21

22

23

24

25

26

27

28

29

30

31

32

33

34

35

36

37

38

39

40

KSWG8

KSWG15

KSWG25

KSWG32

KSWG50

KSWG65

KSWG72

KSWG100

45

54

73

92

111

47

60

85

95

120

40

62

80

100

120

40

60

80

100

120

45

62

80

100

120

40

60

80

100

120

40

60

80

100

120

41

60

80

100

117

13000080

13000080

11000060

11000060

11000060

13000080

13000080

11000060

11000060

11000060

13000080

13000080

11000060

11000060

11000060

13000080

13000080

11000060

11000060

11000060

13000080

13000080

11000060

11000060

11000060

13000080

13000080

11000060

11000060

11000060

13000080

13000080

11000060

11000060

11000060

13000080

13000080

11000060

11000060

11000060

600 1200

600 1200

800 1600

800 1600

1000 2000

1200 2400

1200 2400

1400 2800

0.33

0.33

0.77

0.77

1.48

2.2

2.2

3.4

CR10-5

CR10-6

CR10-8

CR10-10

CR10-12

CR15-4

CR15-5

CR15-7

CR15-8

CR15-10

CR32-3-2

CR32-4-2

CR32-5-2

CR32-6

CR32-8

CR32-3

CR32-5-2

CR32-6

CR32-8-2

CR32-9

CR45-3-2

CR45-4-2

CR45-5-2

CR45-6

CR45-7

CR64-2

CR64-3

CR64-4

CR64-5

CR64-6

CR64-3-2

CR64-4-2

CR64-5-2

CR64-6-2

CR64-7-2

CR90-3-2

CR90-4-2

CR90-5-2

CR90-6-2

CR90-6

2.2

2.2

3.0

4.0

4.0

4.0

4.0

5.5

7.5

ll

5.5

7.5

11

15

15

5.5

11

11

15

18.5

11

15

18.5

22

30

11

18.5

22

30

37

15

18.5

30

30

27

18.5

30

37

45

45

18

60

140

200

350

500

650

950

KSKB-2-2.2

KSKB-2-2.0

KSKB-2-3.0

KSKB-2-4.0

KSKB-2-4.0

KSKB-2-4.0

KSKB-2-4.0

KSKB-2-5.5

KSKB-2-7.5

KSKB-2-11

KSKB-2-5.5

KSKB-2-7.5

KSKB-2-11

KSKB-2-15

KSKB-2-15

KSKB-2-5.5

KSKB-2-11

KSKB-2-11

KSKB-2-15

KSKB-2-18.5

KSKB-2-11

KSKB-2-15

KSKB-2-18.5

KSKB-2-22

KSKB-2-30

KSKB-2-11

KSKB-2-18.5

KSKB-2-22

KSKB-2-30

KSKB-2-37

KSKB-2-15

KSKB-2-18.5

KSKB-2-30

KSKB-2-30

KSKB-2-37

KSKB-2-18.5

KSKB-2-30

KSKB-2-37

KSKB-245

KSKB-2-45

1300

1350

1400

1450

1480

1400

1480

1550

1600

1700

2100

2200

2400

2550

2680

2150

2400

2500

2650

2780

2450

2600

2750

2880

2950

2980

3200

3450

3650

3850

3150

3400

3600

3700

3900

4500

4800

4900

5100

5150

04

R

KSWG Non-negative-pressure (without suction lift) pipe network pressure

boosting stable current water supply whole set equipment

第8頁(yè)

No.

Type Head

(m) XL

Type Power

Water pump (totaling 3 sets with

two for use and one for standby)

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

19

20

21

22

23

24

25

26

27

28

29

30

31

32

33

34

35

KSWG18

KSWG32

KSWG56

KSWG63

KSWG83

KSWG115

KSWG130

42

69

87

104

122

46

58

82

94

118

44

59

83

105

120

40

60

81

102

124

41

61

81

101

122

45

60

80

100

120

40

60

80

102

124

13000080

13000080

11000060

11000060

11000060

13000080

13000080

11000060

11000060

11000060

13000080

13000080

11000060

11000060

11000060

13000080

13000080

11000060

11000060

11000060

13000080

13000080

11000060

11000060

11000060

13000080

13000080

11000060

11000060

11000060

13000080

13000080

11000060

11000060

11000060

600 1200

800 1600

1000 2000

1000 2000

1200 2400

1200 2400

1200 2400

0.33

0.77

1.48

1.48

2.2

2.2

2.2

CR10-5

CR10-8

CR10-10

CR10-12

CR10-14

CR15-4

CR15-5

CR15-7

CR15-8

CR15-10

CR32-3

CR32-4

CR32-6-2

CR32-7

CR32-8

CR32-3

CR32-5-2

CR32-6

CR32-8-2

CR32-9

CR45-2

CR45-3

CR45-4

CR45-5

CR45-6

CR64-2

CR64-3-1

CR64-4-1

CR64-5-2

CR64-6-2

CR64-2

CR64-3

CR64-4

CR64-5

CR64-6

2.2

3.0

4.0

4.0

5.5

4.0

4.0

5.5

7.5

11

5.5

7.5

11

15

15

5.5

11

11

15

18.5

7.5

11

15

18.5

22

11

15

22

30

30

11

18.5

22

30

37

70

200

450

550

780

1100

1250

KSKB-3-2.2

KSKB-3-3.0

KSKB-3-4.0

KSKB-3-4.0

KSKB-3-5.5

KSKB-3-4.0

KSKB-3-4.0

KSKB-3-5.5

KSKB-3-7.5

KSKB-3-11

KSKB-3-5.5

KSKB-3-7.5

KSKB-3-11

KSKB-3-15

KSKB-3-15

KSKB-3-5.5

KSKB-3-11

KSKB-3-11

KSKB-3-15

KSKB-3-18.5

KSKB-3-7.5

KSKB-3-11

KSKB-3-15

KSKB-3-18.5

KSKB-3-22

KSKB-3-11

KSKB-3-15

KSKB-3-22

KSKB-3-30

KSKB-3-30

KSKB-3-11

KSKB-3-18.5

KSKB-3-22

KSKB-3-30

KSKB-3-37

2700

2900

3100

3250

3450

2900

3100

3300

3450

3650

3200

3350

3600

3750

3850

3200

3600

3650

3800

3900

3500

3750

3850

3950

4150

3900

4050

4100

4200

4300

3900

4100

4150

4250

4350

R

05

Model of pressure

stabilizing tank

3 M

Limited volume

User quantity

for reference

Model of frequency

conversion cabinet kg

Approximate

weight

of equipment

Stable current compensator

KSWG ( )

第9頁(yè)

R

06

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

19

20

21

22

23

24

25

26

27

28

29

30

KSWG96

KSWG126

KSWG150

KSWG195

KSWG255

KSWG300

40

60

81

102

124

41

61

81

101

122

44

62

80

106

124

40

60

80

102

124

41

64

86

98

122

41

62

81

102

117

13000080

13000080

11000060

11000060

11000060

13000080

13000080

11000060

11000060

11000060

13000080

13000080

11000060

11000060

11000060

13000080

13000080

11000060

11000060

11000060

13000080

13000080

11000060

11000060

11000060

13000080

13000080

11000060

11000060

11000060

1200 2400

1200 2400

1200 2400

1400 2800

1400 2800

1400 2800

2.2

2.2

2.2

3.8

3.8

3.8

CR32-3

CR32-4

CR32-6

CR32-8-2

CR32-9

CR45-2

CR45-3

CR45-4

CR45-5

CR45-6

CR45-3-2

CR45-4-2

CR45-5-2

CR45-6

CR45-7

CR64-2

CR64-3

CR64-4

CR64-5

CR64-6

CR90-2

CR90-3

CR90-4

CR90-5-2

CR90-6-2

CR90-3-2

CR90-4-2

CR90-5-2

CR90-6-2

CR90-6

5.5

7.5

11

15

18.5

7.5

11

15

18.5

22

11

15

18.5

22

30

11

18.5

22

30

37

15

22

30

37

45

18.5

30

37

45

45

900

1200

1600

2100

2800

3300

KSKB-4-5.5

-4-7.5

-4-11

-4-15

-4-18.5

-4-7.5

-4-11

-4-15

-4-18.5

-4-22

-4-11

-4-15

-4-18.5

-4-22

-4-30

-4-11

-4-18.5

-4-22

-4-30

-4-37

-4-15

-4-22

-4-30

-4-37

-4-45

-4-18.5

-4-30

-4-37

-4-45

-4-45

KSKB

KSKB

KSKB

KSKB

KSKB

KSKB

KSKB

KSKB

KSKB

KSKB

KSKB

KSKB

KSKB

KSKB

KSKB

KSKB

KSKB

KSKB

KSKB

KSKB

KSKB

KSKB

KSKB

KSKB

KSKB

KSKB

KSKB

KSKB

KSKB

3600

3750

3960

4100

4250

3900

4150

4250

4380

4500

4100

4200

4320

4500

4680

4500

4650

4800

4950

5100

4900

5200

5300

5350

5500

5050

5250

5350

5500

5600

No.

Type Head

(m) XL

Type Power

Water pump (totaling 4 sets with

three for use and one for standby)

Model of pressure

stabilizing tank

3 M

Limited volume

User quantity

for reference

Model of frequency

conversion cabinet

kg

Approximate

weight

of equipment

Stable current compensator

KSWG Non-negative-pressure (without suction lift) pipe network pressure

boosting stable current water supply whole set equipment

第10頁(yè)

( )

1.

2.

3.

V =(Q -Q ) t

3 Q (m /h)

3 Q (m /h)

t (h)

KSWG

Note 1. Model selection form of horizontal stainless steel stable current compensator

No.

1

2

3

4

5

Model of non-negative- L H D W B 4- d

pressure tank

h

KSQ-600

KSQ-800

KSQ-1000

KSQ-1200

KSQ-1400

600

800

1000

1200

1400

1200

1600

2000

2400

2800

700

850

1100

1200

1450

80

100

100

125

150

650

1000

1300

1600

1800

350

600

700

850

950

550

700

850

1000

1200

10

12

12

14

14

H

B

K W

L

h

Water outlet pipe

Main water inlet pipe

4- d

D

R

07

The model selection for KSWG non-negative-pressure (without

suction lift) pipe network pressure boosting stable current water supply

whole set equipment is based on the water inlet amount of tap water

(specified by tap water pipe diameter pressure and length etc. conditions),

actual w ater con sumption, height of buildings etc. data. The perfor mance

form of model selection provided by our company complies with the

following principles:

1. The flow indicated in the form is designed according to the unit.

The equipment model is of common model. Our company can redesign

according to special requirements of customers.

2. The equipment flow indicated in the form does not include flow

of standby pump. The quantity of water pump in the form includes two

sets for use.

3. The specification of stable current compensator recommended

in the form is evaluated and calculated accord ing to the conditions that

tap water satisfies customer requirements. If the tap water pipe diameter

is very slim or the pressure is very low and the water inlet amount can't

satisfy the demands at peak time of water use, the volume of stable current

compensator shall be recalculated. The recommended formulae are as

follows:

V volume=(Q outlet-Q inlet) t

3 Q inlet water inlet amount of tap water at peak time of water use (m /h)

3 Q outlet water consumption by customer at peak time of water use (m /h)

t continuous period at peak time of water use (h)

KSWG ( )

第11頁(yè)

Code (model)

13000080

13000105

13000150

13000200

13000250

13000300

13000400

13000600L

11000050

11000060

11000080

11000100

11A00150

11000200

11000300

11000500

11000750

11001000

Note 2. Model selection method of imported pressure stabilizing tank

Total volume

(L)

Regulated volume

(L)

Diameter

(mm)

Height

(mm)

Working pressure

Replace homemade tank

(mm)

80

105

150

200

250

300

400

600

50

60

80

100

150

200

300

500

750

1000

56

74

105

140

175

210

280

420

35

42

56

70

105

140

210

350

525

700

450

500

500

600

630

630

630

750

380

380

450

450

500

550

630

750

750

850

614

615

897

860

970

1135

1510

1555

770

850

850

935

895

1253

1365

1600

2140

2070

0.6

0.6

0.6

0.6

0.6

0.6

0.6

0.6

1

1

1

1

1

1

1

1

1

1

400

400

600

600

800

800

1000

400

400

600

600

800

1000

1200

1.

1

2

3

4

2.

3.

R

08

Unpacking and inspection

1. After unpacking, please check if the following contents are included:

(1) 1 copy of product certification

(2) 1 copy of product use instruction

(3) 1 copy of principle figure of electric control cabinet

(4) 1 copy of equipment installation basic figure

2. Carry out inspection according to drawing s provided and there shall

have no occurrence of sh ortage , damage, rust and corrosion of the

equipment.

3. During the storage, please avoid dampness and exposure to the sun.

KSWG Non-negative-pressure (without suction lift) pipe network pressure

boosting stable current water supply whole set equipment

第12頁(yè)

1

J231

2 0.1

3

24

4 123( ) l 2

3 1 2

3 3 1 3 2

5

6

()1 ( ) 2 ()3

( 0.3Mpa)

( 0.05Mpa)

7

8

9

10

11 90 ( ABB

4020 )

12 MENU

"99 40 ENTER

4001 4020 ENTER

2

ENTER 4014

( 35-42Hz) 4015

( 4020 80 )

SAMI GS 0127

4020 20 3202

( 4020 80 ) 1401 8 3205

( 4020 98 1402 9

4020 0127 0.5Mpa

R

09

1. The construction shal l be made with the basic dimensions of

equipment complying with the basic figure provided by the manufacturer.

The position and elevation shall be in accordance with engineering design

and quality requirements on basic dimensions and position of equipment

in J231.

2. After the equipment is on the designated position, align it with leveler,

with the level ness of vertical and horizontal direction being lower than 0. 1%.

3. After the equipment is installed and leveled, carry out twice grouting

with expansion cement. Carry out tubing after maintaining for 24 hours.

4. The sockets 1, 2 and 3 (yellow, blue and red) of transmissible pressure

gauge are connected with terminals 1, 2 and 3 respectively. Measure the

resistance of transmissible pressure gauge with multimeter. 1 and 2 have

the larger resistance, and the last one is 3. The resistance of 2 is larger than

that of 1. It's better to check with multimeter, or else, wrong wiring may

burn the gauge.

5. The transmissible pressure gauge shall be installed onto pipe network

of users, and general pipe after the outlet check valve.

6. Negative pressure inspection meter is inspected according to

electrical contact pressure gauge. In the electrical contact pressure gauge,

the common point (black wire) is connected with 1 , the upper limit

(red wire) is connected with 2 and the lower limit (green wire) is

connec ted with 3 . The upper limit is the pressure of tap water (genera lly

0.3Mpa) and the lower limit is the pressure that does not produce negative

pressure (generally 0.05Mpa).

7. After the frequency conversion cabinet transmits the power, it is

forbidden to change the parameter of frequency converter.

8. Open the vent valve of water pump and eliminate the gas.

9. After the system is started, maintained or repaired for the first time,

during starting, the water inlet valve shall be opened and the water outlet

valve shall be closed. Check if there is any leakage in the system. If there

is, please eliminate the leakage before starting.

10. First check the rotation direction of water pump when the water

pump operates automatically. If it rotates reversely, please exchange the

position of random two phase lines of power inlet lines, and turn to manual

operation, start the pump manually, and exchange the motor lines of water

pump if the water pump rotates reversely.

11. The water use pressure for user is generally set as 90% of the lift

of water pump when leaving the factory (set from ABB frequency converter

4020).

12. Turn the selector switch to stop , press the MENU button

on the frequency converter and 99 will be displayed. Press the upward

and downwar d button to enter parameter 40 group, press ENTER butto n

and 4001 will be displayed. Press the upward and downward button to

enter parameter 4020, press ENTER button for two seconds and -

will be displayed on the frequency converter. Press the upward and do

wnward button to modify the value of , press ENTER button and the

modification is completed. 4014 is the frequency for frequency conversion

sleeping, which is set as the frequency conversion operation frequency

(about 35-42Hz) when no water is used. 4015 is awakening value, which is

set as the percentage of const ant pressure (generally 80% of 4020). For

modificati on of other parameters, please refer to SAMI, GS user manual

for details. It is noted that 0127 is the displayed value of actual pressure

value of pipe network, refer to the value of 0127 for 4020. For example,

when the pressure of pipe network is 0.5Mpa, 4020 can be set as 20%. 3202

is the lower limit of pressure of whole set system plus pump pressure

(generally 80% of 4020). 1401 is set as 8. 3205 is the upper limit of pressure

of whole set system minus pump pressure (generally 98% of 4020). 1402

is set as 9.

KSWG ( )

第13頁(yè)

ABB400 frequency conversion parameter setting (PID Macro)

9901

9902

9905

9906

9907

9908

9909

9910

2003

1 500V 0.5M

2

3

4

5

0

6

Nominal voltage

Maximum

Nominal frequency

Nominal rotation speed

Nominal power

Power factor

1101

1103

1401

1402

2007

2008

3201

3202

2005

2

0

7

10

26Hz

50Hz

127

Set at the site

0

3203

3204

3205

3206

4001

4002

4003

4014

2006

127

2.5

0.5

0.4

38Hz

0

4015 88 -97

4019 1

4020 look 127

0.5MPa

0.5 0127

4020

If 0.5Mpa is required, dial the

meter value to 0.5 and see the value

of 0127 and set the value into 4020.

2103

1

2

3

R

10

Maximum

Set at the site

Set at the site

Set at the site

Maximum

1. Use 500V low voltage gauge to inspect the insulation of motor,

which shall be above 0.5M .

2. Control instrument and circuit.

3. Fully open water inlet valve of water pump and close water outlet

valve. Open the vent valves of pump in turn and close the vent valves

until the liquid is filled in the pump cavity.

4. Turn the selector switch to the manual position, inch the water

pump under no load, with the operating direct ion same as the direction

indicated by the arrow.

5. Manually start and stop water pumps in turn and check if there

is any abnormal situation during operation of water pumps.

1. The system shall be cleaned and purged before the equipment is

put into operation in order to avoid damage to the equipment caused by

the impurities entering into the pump body.

2. The water pump shall not be operated for a long time under the

condition of full closing of outlet valve, and shall not be operated at the

peak of performance curve, and idle operation is forbidden.

3. If the equipment is not used for a long time, necessary measures

shall be taken to prevent the dirt staining, rusting and corroding of

equipment. In winter when the equipment is not used, anti-freezing and

warming measures shall be taken.

KSWG Non-negative-pressure (without suction lift) pipe network pressure

boosting stable current water supply whole set equipment

第14頁(yè)

Failure

Too large starting load

causes

Troubleshooting

The outlet valve is not closed when starting Stop the valve and start it again

Too large current during operation

1.

2.

3.

4.

5.

1. The interval between the impeller and

pump shell of water pump is too small

2. The pump absorbs impurities

3. The flow is too large and the lift is low

4. The pump shaft bends

5. The voltage is too low

1.

2.

3.

4.

5.

1. Check the impeller interval and repair it

2. Dismantle it and eliminate the impurities

3. Appropriately slow down the outlet valve

4. Dismantle the shaft and straighten it

5. The contact of contactor is in bad contact

There is pressure indicated in the pressure

gauge, but no water output in the water

outlet pipe

Insufficient flow

The equipment is vibrated

The sleeping function of pump can't work

1.

2.

3.

1. The resistance in water outlet pipe is too large

2. The rotation direction of water pump is

not correct

3. The impeller inlet and flow passage are blocked

1.

2.

3.

1. The ring is abraded, large interval between

it and the impeller

2. The outlet valve is not fully opened or is

damaged

3. The pipe network has water leakage

1.

2.

1. The fastening bolt loosens

2. The pump shaft or motor shaft is not balanced

1.

2.

3.

4.

1. The pipe network has leakage

2. The set value of system pressure is too high

3. Idle operation of water pump without water

4. The limited sleeping value is set too low

1.

2.

1. Repair or reassemble the outlet pipe

2. Adjust the phase line of water pump motor

Open the pump shell and eliminate the impurities

1.

2.

3.

1. Replace the ring

2. Fully open outlet valve or replace the

outlet valve

3. Repair or replace the water supply pipe

1.

2.

1. Fasten the bolt

2. Check the value or replace the pump

shaft and motor shaft

1.

2.

3.

4.

1. Check and eliminate leakage point

2. Readjust the set value

3. Check the water inlet of water pump

4. Set the limited sleeping value again

R

11

KSWG()

第15頁(yè)

R

0086-21-57887555

AFTER-SALE SERVICE AND CONSULT TELEPHONE:0086-21-57887555

第16頁(yè)

http://www.ksmp.cn E-mail:ksmp@kspump.com

http://www.ksmp.cn E-mail:ksmp@kspump.com

20110408210

百萬(wàn)用戶使用云展網(wǎng)進(jìn)行微信翻頁(yè)書(shū)制作,只要您有文檔,即可一鍵上傳,自動(dòng)生成鏈接和二維碼(獨(dú)立電子書(shū)),支持分享到微信和網(wǎng)站!
收藏
轉(zhuǎn)發(fā)
下載
免費(fèi)制作
其他案例
更多案例
免費(fèi)制作
x
{{item.desc}}
下載
{{item.title}}
{{toast}}