PMF635A 電能質(zhì)量在線監(jiān)測(cè)裝置(單回路)技術(shù)及使用說明書(Ver3.2)許昌智能繼電器股份有限公司XUCHANG INTELLIGENT RELAY CO.,LTD.
PMF635A 電能質(zhì)量在線監(jiān)測(cè)裝置(單回路)技術(shù)及使用說明書(Ver3.2)許昌智能繼電器股份有限公司XUCHANG INTELLIGENT RELAY CO.,LTD.
PMF635A 電能質(zhì)量在線監(jiān)測(cè)裝置(單回路)I
目錄
1 裝置簡(jiǎn)介···················································································································· 11.1 關(guān)于本說明書······················································································································ 11.2 產(chǎn)品清單······························································································································ 12 參數(shù)規(guī)格···················································································································· 22.1 常規(guī)參數(shù)······························································································································ 22.1.1 機(jī)械尺寸··················································································································· 22.1.2 電源··························································································································· 22.1.3 顯示··························································································································· 22.1.4 存儲(chǔ)··························································································································· 22.1.5 環(huán)境··························································································································· 22.1.6 標(biāo)準(zhǔn)··························································································································· 22.1.7 電磁兼容性··············································································································· 22.1.8 環(huán)境可靠性··············································································································· 22.2 測(cè)量參數(shù)······························································································································ 32.2.1 測(cè)量項(xiàng)目··················································································································· 32.2.2 輸入?yún)?shù)··················································································································· 32.2.3 頻率··························································································································· 32.2.4 電壓 1/2 有效值、電流 1/2 有效值·········································································32.2.5 電壓有效值··············································································································· 32.2.6 電流有效值··············································································································· 32.2.7 諧波電壓、諧波電流·······························································································42.2.8 間諧波電壓、間諧波電流·······················································································42.2.9 高次諧波電壓、高次諧波電流···············································································42.2.10 有功功率、無功功率、視在功率·········································································42.2.11 功率因數(shù)················································································································· 42.2.12 電壓不平衡度、電流不平衡度(負(fù)序、零序)·················································42.2.13 電壓波動(dòng)················································································································· 52.2.14IEC 閃變···················································································································52.2.15 沖擊電流················································································································· 52.2.16 電壓暫升、電壓暫降、短時(shí)中斷·········································································53 基本操作···················································································································· 63.1 安全須知······························································································································ 63.2 裝置外觀及結(jié)構(gòu)·················································································································· 63.3 平臺(tái)說明······························································································································ 73.4 接口說明······························································································································ 73.5 按鍵功能說明······················································································································ 94 接線說明···················································································································114.1 接線要求·····························································································································114.2 典型接線圖························································································································ 115 軟件簡(jiǎn)介·················································································································· 135.1 菜單結(jié)構(gòu)···························································································································· 135.2 界面 ·································································································································· 14
PMF635A 電能質(zhì)量在線監(jiān)測(cè)裝置(單回路)II
6 實(shí)時(shí)波形·················································································································· 156.1 電壓/電流·························································································································· 156.2 有效值/相位······················································································································· 156.3 功率 ·································································································································· 166.4 波動(dòng)閃變···························································································································· 166.5 電能 ·································································································································· 167 諧波分析·················································································································· 187.1 諧波 ·································································································································· 187.2 間諧波································································································································ 187.3 高頻諧波···························································································································· 197.4 諧波功率···························································································································· 198 錄波分析·················································································································· 218.1 定時(shí)錄波···························································································································· 218.2 觸發(fā)錄波···························································································································· 219 事件告警·················································································································· 239.1 暫態(tài)告警···························································································································· 239.2 穩(wěn)態(tài)告警···························································································································· 2310 參數(shù)設(shè)置················································································································ 2510.1 基本參數(shù)·························································································································· 2510.2 暫態(tài)參數(shù)·························································································································· 2610.3 穩(wěn)態(tài)參數(shù)·························································································································· 2610.4 諧波電流·························································································································· 2710.5 接線方式·························································································································· 2811 系統(tǒng)設(shè)置·················································································································3111.1 系統(tǒng)信息·························································································································· 3111.2 網(wǎng)絡(luò)設(shè)置·························································································································· 3111.3 協(xié)議設(shè)置·························································································································· 3211.4 校時(shí)設(shè)置·························································································································· 3211.5 繼電器·······························································································································3311.6 高級(jí)設(shè)置·························································································································· 3412 免責(zé)申明················································································································ 36
PMF635A 電能質(zhì)量在線監(jiān)測(cè)裝置(單回路)1
1 裝置簡(jiǎn)介
1.1 關(guān)于本說明書
本說明書提供如何以安全的方式使用電能質(zhì)量監(jiān)測(cè)裝置的準(zhǔn)確和完整的說明。說明書中詳細(xì)介紹了安全、規(guī)范的操作要領(lǐng),以及各種測(cè)量模式的使用流程。請(qǐng)用戶在使用儀器前,完整的閱讀本說明書。
1.2 產(chǎn)品清單
在儀器出廠時(shí)會(huì)配置一些標(biāo)準(zhǔn)套件,以滿足使用。標(biāo)準(zhǔn)產(chǎn)品套件包括下列物品:表 1- 1 套件清單列表
編號(hào) 名稱 數(shù)量1 PMF635A 主機(jī) 1 臺(tái)2 連接端子排 1 套3 出廠試驗(yàn)報(bào)告 1 套
PMF635A 電能質(zhì)量在線監(jiān)測(cè)裝置(單回路)2
2 參數(shù)規(guī)格
2.1 常規(guī)參數(shù)
2.1.1 機(jī)械尺寸
尺寸 144(寬)×144(高)×196(長)mm重量 約 2.5kg
2.1.2 電源
電源輸入電壓 +85VAC~+265VAC 110V~370V DC
2.1.3 顯示
尺寸 5.0 寸
色彩 16.7M
分辨率 800×480
亮度 250 cd/m2 (Typ.)
對(duì)比度 600:1(Typ)
可視角度 50/70/70/70 (Typ.)(CR≥10) (上/下/左/右)
2.1.4 存儲(chǔ)
類型 SD 卡(內(nèi)置)
容量 8GB
2.1.5 環(huán)境
工作環(huán)境 室內(nèi)使用,-20℃~+70℃,濕度 90rh%以下
存儲(chǔ)環(huán)境 室內(nèi)保存,-40℃~+85℃,濕度 95rh%以下(不凝結(jié))
安全性 絕緣電阻≥5MΩ,絕緣強(qiáng)度:2kV(50Hz,1min)
2.1.6 標(biāo)準(zhǔn)
測(cè)量方法 IEC61000-4-30
測(cè)量性能 IEC61000-4-30 A 級(jí)
閃變 IEC61000-4-15
諧波 IEC61000-4-7
2.1.7 電磁兼容性
標(biāo)準(zhǔn)
等級(jí) 3:GB/T 17626.2-2006 靜電放電抗擾度
等級(jí) 3:GB/T 17626.3-2006 射頻電磁場(chǎng)輻射抗擾度
等級(jí) 3:GB/T 17626.4-2008 電快速瞬變脈沖群抗擾度
等級(jí) 3:GB/T 17626.5-2008 浪涌(沖擊)抗擾度
等級(jí) 3:GB/T 17626.8-2006 工頻磁場(chǎng)抗擾度
等級(jí) 3:GB/T 17626.9-1998 脈沖磁場(chǎng)抗擾度
等級(jí) 3:GB/T 17626.12-1998 振蕩波抗擾度
2.1.8 環(huán)境可靠性
標(biāo)準(zhǔn)
GB/T 2423.1-2008 低溫
GB/T 2423.2-2008 高溫
GB/T 2423.4-2008 交變濕熱
GB/T 2423.5-1995 沖擊
PMF635A 電能質(zhì)量在線監(jiān)測(cè)裝置(單回路)3
GB/T 2423.10-2008 振動(dòng)
GB/T 2423.22-2002 溫度變化
2.2 測(cè)量參數(shù)
2.2.1 測(cè)量項(xiàng)目
測(cè)量類型 測(cè)量項(xiàng)
電壓/電流/頻率 有效值、峰值、頻率偏差等
三相不平衡 電壓/電流正序值、負(fù)序值、負(fù)序不平衡度、零序不平衡度諧波 電壓/電流 63 次諧波、50 組間諧波、35 組高次諧波、諧波含有率、諧波功率波動(dòng)/閃變 短閃變、長閃變、電壓波動(dòng)值
功率/電能 有功、無功、視在、功率因數(shù)等
事件記錄
電壓暫升、電壓暫降、電壓中斷、沖擊電流、電壓電流總畸變率、奇偶次諧波含有率、電壓電流不平衡、頻率、短閃變、長閃
2.2.2 輸入?yún)?shù)
測(cè)量線路 三相三線/三相四線制
測(cè)量線路基本頻率 50Hz輸入通道數(shù) 電壓 4 通道、電流 4 通道
測(cè)量量程 電壓測(cè)量量程:標(biāo)稱值 57.74V/100V/230V,最大值 460V;電流測(cè)量量程:標(biāo)稱值 5A 最大值 10A
2.2.3 頻率
測(cè)量方式 由 10 個(gè)波形(50Hz 時(shí))運(yùn)算
顯示方式 顯示一個(gè)通道的頻率值
測(cè)量量程/分辨率 50.0000Hz/0.001Hz測(cè)量帶寬 42.5000~57.5000Hz測(cè)量精度 ±0.001Hz 2.2.4 電壓 1/2 有效值、電流 1/2 有效值
測(cè)量方式 每兩個(gè)周波運(yùn)算一次,每周波去 1/2 周波組成 1 個(gè)波形運(yùn)算測(cè)量量程/分辨率 Max 電壓:460V/0.01,Max 電流:10A/0.001A
測(cè)量精度 標(biāo)稱電壓的 0.2%
2.2.5 電壓有效值
測(cè)量方式 由 10 個(gè)波形(50Hz 時(shí))運(yùn)算
顯示方式 每通道的電壓有效值
測(cè)量量程/分辨率 Max 電壓:460V/0.01V
測(cè)量精度 標(biāo)稱電壓的 0.1%
2.2.6 電流有效值
測(cè)量方式 由 10 個(gè)波形(50Hz 時(shí))運(yùn)算
顯示方式 每通道的電流有效值
測(cè)量量程/分辨率 Max 電流:10A/0.001A
測(cè)量精度 標(biāo)稱電流的 0.1%
PMF635A 電能質(zhì)量在線監(jiān)測(cè)裝置(單回路)4
2.2.7 諧波電壓、諧波電流
測(cè)量方式 符合 IEC61000-4-7,分析窗口幅度 10 個(gè)周波
窗口點(diǎn)數(shù) 每 10 個(gè)周波共 5120 點(diǎn)
顯示方式 表格圖
測(cè)量次數(shù) 1 次~63 次
測(cè)量量程/分辨率 Max 電壓:460V /0.005,
測(cè)量精度
電壓諧波大于 1%標(biāo)稱值時(shí):誤差小于 5%設(shè)定值
電壓諧波小于 1%標(biāo)稱值時(shí):誤差小于 0.05% 標(biāo)稱電壓值電流諧波大于 3%標(biāo)稱值時(shí):誤差小于 5% 設(shè)定值
電流諧波小于 3%標(biāo)稱值時(shí):誤差小于 0.15%標(biāo)稱電壓值
2.2.8 間諧波電壓、間諧波電流
測(cè)量方式 符合 IEC61000-4-7,分析窗口幅度 10 個(gè)周波
窗口點(diǎn)數(shù) 每 10 個(gè)周波共 5120 點(diǎn)
顯示方式 表格圖
測(cè)量次數(shù) 1~49 組
測(cè)量精度
電壓諧波大于 1%標(biāo)稱值時(shí):誤差小于 5%設(shè)定值
電壓諧波小于 1%標(biāo)稱值時(shí):誤差小于 0.05% 標(biāo)稱電壓值電流諧波大于 3%標(biāo)稱值時(shí):誤差小于 5%設(shè)定值
電流諧波小于 3%標(biāo)稱值時(shí):誤差小于 0.15% 標(biāo)稱電壓值2.2.9 高次諧波電壓、高次諧波電流
測(cè)量方式 符合 IEC61000-4-7,分析窗口幅度 10 個(gè)周波
窗口點(diǎn)數(shù) 每 10 個(gè)周波共 5120 點(diǎn)
顯示方式 表格圖
測(cè)量次數(shù) 1~35 組
測(cè)量精度
電壓諧波大于 1%標(biāo)稱值時(shí):誤差小于 5%設(shè)定值
電壓諧波小于 1%標(biāo)稱值時(shí):誤差小于 0.05% 標(biāo)稱電壓值電流諧波大于 3%標(biāo)稱值時(shí):誤差小于 5%設(shè)定值
電流諧波小于 3%標(biāo)稱值時(shí):誤差小于 0.15% 標(biāo)稱電壓值2.2.10 有功功率、無功功率、視在功率
測(cè)量方式
有功功率:每 10 個(gè)周波進(jìn)行運(yùn)算
視在功率:由電壓電流的有效值來運(yùn)算
無功功率:由視在功率、有功功率來計(jì)算
顯示方式 表格圖
測(cè)量量程/分辨率 根據(jù)電壓電流量程來確定
測(cè)量精度 ±0.5%設(shè)定值
2.2.11 功率因數(shù)
測(cè)量方式 由電壓有效值、電流有效值、有功功率進(jìn)行計(jì)算
顯示方式 實(shí)時(shí)數(shù)據(jù)顯示
測(cè)量量程/分辨率 -1.0000~1.0000
測(cè)量精度 ±0.01
2.2.12 電壓不平衡度、電流不平衡度(負(fù)序、零序)
測(cè)量方式 三相三線制或三相四線時(shí),使用三相的基波成分來計(jì)算
顯示方式 表格圖、矢量圖
PMF635A 電能質(zhì)量在線監(jiān)測(cè)裝置(單回路)5
測(cè)量量程 0.00%~100%
測(cè)量精度 電壓不平衡度:±0.15%;電流不平衡度:±1%
2.2.13 電壓波動(dòng)
測(cè)量方式 半波方均值來計(jì)算
顯示方式 表格圖
測(cè)量量程 0.00%~100%
測(cè)量精度 ±5%
2.2.14IEC 閃變
測(cè)量項(xiàng)目 短閃變(Pst)、長閃變(Plt)
測(cè)量方式 根據(jù) IEC61000-4-15 連續(xù)測(cè)量 10 分鐘的 Pst,連續(xù)測(cè)量并計(jì)算2 小時(shí)Plt
顯示方式 表格圖
測(cè)量量程 0~20
測(cè)量精度 ±5%
2.2.15 沖擊電流
測(cè)量方式 電流的半波有效值超過設(shè)定值的正向沖擊電流
顯示方式 沖擊電流波形、沖擊電流最大值
測(cè)量精度 0.1%
2.2.16 電壓暫升、電壓暫降、短時(shí)中斷
測(cè)量方式
暫升:電壓半波有效值正方向超過設(shè)定值時(shí),判定為暫升暫降:電壓半波有效值負(fù)方向超過設(shè)定值時(shí),判定為暫降短時(shí)中斷:電壓半波有效值負(fù)方向超過設(shè)定值時(shí),判定為瞬間中斷顯示方式 暫升、暫降、短時(shí)中斷的波形持續(xù)時(shí)間、幅度等
測(cè)量精度 0.1%
PMF635A 電能質(zhì)量在線監(jiān)測(cè)裝置(單回路)6
3 基本操作
3.1 安全須知
PMF635A 電能質(zhì)量在線監(jiān)測(cè)裝置遵循:GB/T 15479-1995。
在操作分析儀之前,請(qǐng)仔細(xì)閱讀本說明書中關(guān)于操作安全和操作規(guī)范的相關(guān)描述。否則,可能會(huì)產(chǎn)生意外,對(duì)使用者人身或者設(shè)備造成傷害。
為避免觸電或引起火災(zāi),請(qǐng)注意下列安全條款:
? 使用裝置及其配件之前,請(qǐng)先完整閱讀用戶使用說明書。? 為盡可能保障使用者人身安全,請(qǐng)?jiān)诙嗳伺惆榄h(huán)境下使用裝置。? 切勿在爆炸性的氣體附近使用裝置。
? 只能使用裝置所附帶,或經(jīng)本公司指示適用于本電能質(zhì)量在線監(jiān)測(cè)裝置的連接導(dǎo)線。
? 使用前,仔細(xì)檢查裝置連接導(dǎo)線、端子排等附件絕緣部分是否有損壞的情況。如有損壞,應(yīng)立即更換。
? 對(duì)于未使用的連接導(dǎo)線、端子排,應(yīng)拆卸單獨(dú)放置。
? 接地輸入端僅可作為裝置接地之用,不可在該端施加任何電壓。? 不要施加超出裝置額定值的輸入電壓。
? 不要施加超出裝置所標(biāo)額定電壓值的電壓。
? 在安裝和拆卸連接線時(shí)要特別小心:注意斷開被測(cè)設(shè)備的電源或穿上合適的防護(hù)服。
? 不要將金屬物件插入接頭。
3.2 裝置外觀及結(jié)構(gòu)
裝置外觀如圖 3- 1 所示:
圖 3- 1 整機(jī)外觀圖
裝置采用整面板形式,面板上包括液晶顯示器、信號(hào)指示燈、操作鍵盤等。采用加強(qiáng)型單元機(jī)箱,能有效抵抗強(qiáng)振動(dòng)與強(qiáng)干擾,確保裝置在條件惡劣的環(huán)境條件下仍具備高可靠性。不論組屏或分散安裝均不需加設(shè)交、直流輸入抗干擾模塊。裝置的外形尺寸如圖3- 2 所示:
PMF635A 電能質(zhì)量在線監(jiān)測(cè)裝置(單回路)7
插件1
插件2
插件3
圖 3- 2 外形尺寸
3.3 平臺(tái)說明
電能質(zhì)量在線監(jiān)測(cè)裝置采用許昌智能繼電器股份有限公司新一代32 位基于ARM+DSP雙核技術(shù)的通用硬件平臺(tái)。全封閉機(jī)箱,硬件電路采用后插拔式的插件結(jié)構(gòu),CPU電路板采用 6 層板、元器件采用表面貼裝技術(shù),裝置強(qiáng)弱電回路、開入開出回路合理布局,抗干擾能力強(qiáng)。
軟件平臺(tái)采用自主開發(fā)的 RTOS 系統(tǒng) Aworks,Aworks 平臺(tái)經(jīng)過許昌智能繼電器股份有限公司的嚴(yán)格測(cè)試,在其內(nèi)部多個(gè)項(xiàng)目中已有應(yīng)用實(shí)踐,可以保證軟件系統(tǒng)的高度可靠性。3.4 接口說明
圖 3- 3 接口說明圖
表 3- 1 接口信號(hào)說明
插件 1
PMF635A 電能質(zhì)量在線監(jiān)測(cè)裝置(單回路)8
名稱 功能 安裝說明NET 網(wǎng)線插座 連接以太網(wǎng),RJ45 水晶頭RS232 調(diào)試串口 輸出系統(tǒng)調(diào)試信息GPS GPS_CLK GPS 硬件校時(shí)脈沖輸入信號(hào)GND GPS_GND GPS 硬件校時(shí)脈沖輸入信號(hào)地485A RS485_A RS-485 差分信號(hào)A
485B RS485_B RS-485 差分信號(hào)B
COM RS485_COM1 RS-485 隔離地插件 2
名稱 功能 安裝說明IA 電流采集輸入端 A A 相電流采集輸入通道IA’ 電流采集輸出端 A A 相電流采集輸出通道IB 電流采集輸入端 B B 相電流采集輸入通道IB’ 電流采集輸出端 B B 相電流采集輸出通道IC 電流采集輸入端 C C 相電流采集輸入通道IC’ 電流采集輸出端 C C 相電流采集輸出通道IO 電流采集輸入端 O 中性線電流采集輸入通道IO’ 電流采集輸出端 O 中性線電流采集輸出通道UA 通道 A A 相電壓采集通道UB 通道 B B 相電壓采集通道UC 通道 C C 相電壓采集通道UN 通道 N 中性線電壓采集通道AGND 參考地 電壓信號(hào)采集參考公共地插件 3
名稱 功能 安裝說明DO1 繼電器 1
繼電器 1 輸出端
觸電負(fù)載:阻性,250VAC 8A
切換電壓:400VAC/300VDC
DO2 繼電器 2
繼電器 2 輸出端
觸電負(fù)載:阻性,250VAC 8A
切換電壓:400VAC/300VDC
DI1 開漏輸入信號(hào) 光耦 1 輸入端
PMF635A 電能質(zhì)量在線監(jiān)測(cè)裝置(單回路)9
交流輸入范圍:85V~265V
直流輸入范圍:110V~370V
GND1 開漏輸入信號(hào)地
DI2 開漏輸入信號(hào) 光耦 2 輸入端
交流輸入范圍:85V~265V
直流輸入范圍:110V~370V
GND2 開漏輸入信號(hào)地
L/+ 電源輸入
連接到火線
交流輸入范圍:85V~265V
直流輸入范圍:110V~370V
N/- 電源輸入
連接到零線
交流輸入最大值: 265V
直流輸入最大值: 370V
大地 連接到大地
外殼地 連接到大地
主要插件說明
1) 插件 1:包含微處理器 CPU、RAM、ROM、Flash Memory、網(wǎng)絡(luò)通訊電路等;此外還包括 GPS 報(bào)文對(duì)時(shí)、IRIG-B 碼對(duì)時(shí)接口。本插件采用6 層印制板和表面貼裝工藝,采用了多種抗干擾措施,大大提高了抗干擾性能。高性能的微處理器CPU為 32 位雙核處理器,主頻達(dá) 600MHz。集成電路全部采用工業(yè)品或軍品,使得裝置有很高的穩(wěn)定性和可靠性。
2) 插件 2:交流變換部分包括電流變換器 TA 和電壓變換器 TV,用于將系統(tǒng)TA、TV的二次側(cè)電流、電壓信號(hào)轉(zhuǎn)換為弱電信號(hào),供保護(hù)插件轉(zhuǎn)換,并起強(qiáng)弱電隔離作用。本插件的 6 個(gè) TA 分別變換 IA、IA’、IB、IB’、IC、IC’、IO、IO’六個(gè)電流量,4 個(gè)TV分別變換母線電壓 UA、UB、UC、UN。
3) 插件 3:將外部提供的交或直流電源轉(zhuǎn)換為監(jiān)測(cè)裝置工作所需電壓。本模塊輸入直流 110V~370V 或交流 85V~265V (根據(jù)需要選擇相應(yīng)規(guī)格),輸出+5V。+5V 電壓用于裝置數(shù)字器件工作,再通過轉(zhuǎn)換電路輸出±9V 電壓用于 A/D 采樣。還包括兩路開入和兩路繼電器輸出。
3.5 按鍵功能說明
裝置共有 6 個(gè)按鍵,全部位于屏幕下側(cè),面板布局如圖 3-4 所示:
PMF635A 電能質(zhì)量在線監(jiān)測(cè)裝置(單回路)10
圖 3- 4 面板布局效果圖
表 3- 2 面板按鍵功能說明表
按鍵 功能說明
“確認(rèn)”按鍵,用于在主顯示區(qū)域確定操作,或在菜單區(qū)域進(jìn)入子菜單,或從菜單區(qū)域切換到主顯示區(qū)域
“取消”按鍵,用于取消操作,或在主顯示區(qū)域返回菜單區(qū)域,或在菜單區(qū)域返回上一次菜單
“向上”按鍵,用于在主顯示區(qū)域或菜單區(qū)域向上切換
“向左”按鍵,用于在主顯示區(qū)域向左切換,或菜單區(qū)域向主顯示區(qū)域切換“向右”按鍵,用于在主顯示區(qū)域向右切換,或主顯示區(qū)域向菜單區(qū)域切換“向下”按鍵,用于在主顯示區(qū)域或菜單區(qū)域向下切換
表 3- 3 面板指示燈功能說明表
指示燈 功能說明
亮:電源正常;滅:電源故障或未接通電源
閃爍:3 下 - 有告警事件發(fā)生,5 下 - 有暫態(tài)事件發(fā)生;滅:無暫態(tài)和告警事件
PMF635A 電能質(zhì)量在線監(jiān)測(cè)裝置(單回路)11
4 接線說明
4.1 接線要求
在裝置的后面板有 4 個(gè)插件,分別為電源插件、交流插件、I/O 插件和CPU插件。在開始接線之前,須先根據(jù)將要測(cè)量的電力系統(tǒng)線路電壓、頻率及接線方式等需求,設(shè)置好分析儀器。若有可能,請(qǐng)盡量斷開電源系統(tǒng),再做接線操作,并盡可能穿戴防護(hù)設(shè)備。接線前要將連接導(dǎo)線擰緊,以防導(dǎo)線絲裸露在端子排外面發(fā)生短接,接線時(shí)請(qǐng)按照裝置后面板各插件所示參數(shù)相對(duì)應(yīng)接線,要將螺母擰緊,以免發(fā)生松動(dòng)。
4.2 典型接線圖
PMF635A 共支持 3 種測(cè)量模式,在連接測(cè)量導(dǎo)線之前,請(qǐng)正確配置儀器的測(cè)量模式,詳細(xì)流程見后面接線方式配置。各種測(cè)量模式的接線,請(qǐng)參考下面連線示意圖。典型接線圖包括三種,見以下各圖:
圖 4- 1 三相四線星形接法
圖 4- 2 三相三線星形接法
PMF635A 電能質(zhì)量在線監(jiān)測(cè)裝置(單回路)12
圖 4- 3 三相三線三角形接法
注:圖片中各通道的命名與設(shè)備插件 2 絲印文字一一對(duì)應(yīng)。
PMF635A 電能質(zhì)量在線監(jiān)測(cè)裝置(單回路)13
5 軟件簡(jiǎn)介
PMF635A 多功能電能質(zhì)量監(jiān)測(cè)儀具有強(qiáng)大的測(cè)量、運(yùn)算以及分析能力,測(cè)量結(jié)果準(zhǔn)確無誤, 界面簡(jiǎn)潔優(yōu)雅,提供最好的用戶體驗(yàn),讓您了解當(dāng)前電能各項(xiàng)參數(shù),最快定位電網(wǎng)問題。設(shè)備終端軟件基于許昌智能繼電器股份有限公司自主研發(fā)的嵌入式實(shí)時(shí)操作系統(tǒng)Aworks 開發(fā),系統(tǒng)的可靠性高,穩(wěn)定性強(qiáng),支持豐富的底層硬件,具有強(qiáng)大的可定制性。5.1 菜單結(jié)構(gòu)
PMF635A 在電能監(jiān)測(cè)方面提供豐富的數(shù)據(jù)項(xiàng),幫助您發(fā)現(xiàn)與定位電能問題,同時(shí)提供許多人性化功能,整體功能如表 5-1 所列:
表 5- 1 PMF635A 整體功能
功能名 子菜單 功能說明
實(shí)時(shí)波形
電壓|電流 實(shí)時(shí)顯示三相電壓、電流波形及有效值
有效值|相位
實(shí)時(shí)顯示電壓、電流有效值、相位角、序分量以及不平衡度實(shí)時(shí)顯示電壓偏差值
功率 實(shí)時(shí)顯示有功功率、無功功率、視在功率、位移功率因數(shù)、功率因數(shù)波動(dòng)閃變 實(shí)時(shí)顯示電壓波動(dòng)、短閃變(PST)、長閃變(PLT)電能 顯示當(dāng)日/月消耗的電能以及需量相關(guān)信息
諧波分析
諧波 實(shí)時(shí)顯示電壓、電流 1-63 次諧波有效值、含有率、相位角間諧波 實(shí)時(shí)顯示電壓、電流 0-49 次間諧波有效值、含有率高頻諧波 實(shí)時(shí)顯示電壓、電流 1-35 次高頻諧波有效值、含有率諧波功率 實(shí)時(shí)顯示 1-63 次諧波功率有效值
錄波分析
定時(shí)錄波 手動(dòng)開始錄波或定時(shí)預(yù)約錄波,可設(shè)置錄波時(shí)間
觸發(fā)錄波 開啟或關(guān)閉告警錄波以及電平錄波
事件告警
暫態(tài)事件
按日期查詢?cè)O(shè)備記錄的暫態(tài)事件,包括電壓暫升、電壓暫降、電壓中斷、沖擊電流
穩(wěn)態(tài)事件
按日期查詢?cè)O(shè)備記錄的穩(wěn)態(tài)事件,包括電壓越限、頻率越限、諧波越限等
參數(shù)設(shè)置
基本參數(shù) 設(shè)置電壓、電流變比、標(biāo)稱電壓、存儲(chǔ)周期、電壓等級(jí)等暫態(tài)參數(shù) 設(shè)置暫態(tài)事件越限閾值
穩(wěn)態(tài)參數(shù) 設(shè)置穩(wěn)態(tài)事件越限閾值
諧波電流 設(shè)置 2-25 次電流諧波越限閾值
接線方式 設(shè)置設(shè)備接線方式
系統(tǒng)設(shè)置
系統(tǒng)信息 查看設(shè)備序列號(hào)、軟件版本、硬件版本、DSP 版本以及FPGA 版本網(wǎng)絡(luò)設(shè)置 設(shè)置設(shè)備網(wǎng)絡(luò)參數(shù)
協(xié)議設(shè)置 設(shè)置通信協(xié)議參數(shù),包括 IEC-103、Modbus-485、Modbus-TCP
PMF635A 電能質(zhì)量在線監(jiān)測(cè)裝置(單回路)14
校時(shí)設(shè)置 設(shè)置校時(shí)方式,包括手動(dòng)校時(shí)、SNTP、B 碼、PPS
繼電器 設(shè)置繼電器 1 和繼電器 2 關(guān)聯(lián)方式
高級(jí)設(shè)置 設(shè)置系統(tǒng)語言及修改設(shè)備密碼
5.2 界面
PMF635A 多功能電能質(zhì)量監(jiān)測(cè)儀主界面以簡(jiǎn)潔優(yōu)雅為主,各個(gè)圖標(biāo)代表各個(gè)功能模塊,選中圖標(biāo)點(diǎn)擊【ENTER】鍵進(jìn)入對(duì)應(yīng)功能頁面,主界面如圖5-1 所示:圖 5- 1 設(shè)備主菜單界面圖
子頁面由右側(cè)導(dǎo)航菜單與左側(cè)展示區(qū)域兩部分組成,通過【ENTER】鍵與【ESC】鍵在兩個(gè)區(qū)域切換,在導(dǎo)航區(qū)通過上下鍵切換選項(xiàng)卡,【ENTER】進(jìn)入展示區(qū)進(jìn)行編輯參數(shù),【ESC】回退到主菜單。
圖 5- 2 參數(shù)設(shè)置-基本參數(shù)
PMF635A 電能質(zhì)量在線監(jiān)測(cè)裝置(單回路)15
6 實(shí)時(shí)波形
“實(shí)時(shí)波形”頁面顯示當(dāng)前監(jiān)測(cè)到的各項(xiàng)電網(wǎng)參數(shù),主要包括電壓(電流)有效值、系統(tǒng)頻率、電壓偏差、相位角(向量圖)、電能功率以及波動(dòng)閃變的實(shí)時(shí)數(shù)據(jù),可以第一時(shí)間了解到電網(wǎng)用電情況。
6.1 電壓/電流
導(dǎo)航菜單選擇“電壓/電流”選項(xiàng)卡,可以看到電壓/電流各相的波形圖、有效值以及頻率,相位與波形線顏色對(duì)應(yīng)情況:A 相-黃、 B 相-綠、C 相-紅。
圖 6- 1 實(shí)時(shí)波形-電壓/電流
6.2 有效值/相位
導(dǎo)航菜單選擇“有效值/相位”選項(xiàng)卡, 可以看到電壓/電流的正/負(fù)/零序分量、零/負(fù)序不平衡、有效值、相位角以及電壓偏差,電壓/電流相位角通過向量圖直觀的展示。圖 6- 2 實(shí)時(shí)波形-有效值/相位
PMF635A 電能質(zhì)量在線監(jiān)測(cè)裝置(單回路)16
6.3 功率
導(dǎo)航菜單選擇“功率”選項(xiàng)卡,可以看有功功率(W)、無功功率(var)、視在功率(VA)、位移功率因數(shù)以及功率因數(shù),功率電能數(shù)據(jù)項(xiàng)實(shí)時(shí)通過 DSP 計(jì)算并將值顯示于表格。圖 6- 3 實(shí)時(shí)波形-功率
單位說明:
W:有用功率單位,瓦特
var:無用功率單位,乏
VA:視在功率單位,伏安
6.4 波動(dòng)閃變
導(dǎo)航菜單選擇“波動(dòng)閃變”選項(xiàng)卡,可以看到波動(dòng)、短閃變(pst)、長閃變(plt)。圖 6-4 實(shí)時(shí)波形-波動(dòng)閃變
6.5 電能
導(dǎo)航菜單選擇“電能”選項(xiàng)卡,可已看到有功功率、無功功率以及視在功率消耗的電能量,同時(shí)可查看當(dāng)前需量值、最大需量值以及最大需量出現(xiàn)的時(shí)間。
PMF635A 電能質(zhì)量在線監(jiān)測(cè)裝置(單回路)17
圖 6-5 實(shí)時(shí)波形-電能
PMF635A 電能質(zhì)量在線監(jiān)測(cè)裝置(單回路)18
7 諧波分析
“諧波分析”頁面主要顯示諧波、間諧波、高頻諧波和諧波功率相應(yīng)的電能參數(shù),該部分?jǐn)?shù)據(jù)為實(shí)時(shí)數(shù)據(jù),計(jì)算準(zhǔn)確無誤,其中諧波數(shù)據(jù)項(xiàng)能計(jì)算到 63 次:1. 電壓/電流諧波:有效值、含有率、相位角
2. 電壓/電流間諧波:有效值、含有率
3. 電壓/電流高頻諧波:有效值
4. 諧波功率:有效值
7.1 諧波
導(dǎo)航菜單選擇“諧波”選項(xiàng)卡,可以看到 1~63 次電壓、電流諧波有效值、含有率、相位角表格圖,通過將光標(biāo)定位到選項(xiàng)框按上下鍵,切換電壓/電流、有效值/含有率/相位角以及頁碼查看更多數(shù)據(jù)項(xiàng)。
圖 7- 1 諧波分析-諧波
7.2 間諧波
導(dǎo)航菜單選擇“間諧波”選項(xiàng)卡,可以看到各個(gè)中心頻率的電壓、電流間諧波有效值與含有率表格圖,通過將光標(biāo)定位到選項(xiàng)框按上下鍵,切換電壓/電流、有效值/含有率以及頁碼查看更多數(shù)據(jù)項(xiàng)。
PMF635A 電能質(zhì)量在線監(jiān)測(cè)裝置(單回路)19
圖 7- 2 諧波分析-間諧波
7.3 高頻諧波
導(dǎo)航菜單選擇“高頻諧波”選項(xiàng)卡,可以看到各個(gè)中心頻率的電壓、電流高頻諧波有效值表格圖,通過將光標(biāo)定位到選項(xiàng)框按上下鍵,切換電壓/電流以及頁碼查看更多數(shù)據(jù)項(xiàng)。圖 7- 3 諧波分析-高次諧波
7.4 諧波功率
導(dǎo)航菜單選擇“諧波功率”選項(xiàng)卡,可以看到各次高頻諧波有效值表格圖,通過將光標(biāo)定位到選項(xiàng)框按上下鍵,切換頁碼查看更多數(shù)據(jù)項(xiàng)。
PMF635A 電能質(zhì)量在線監(jiān)測(cè)裝置(單回路)20
圖 7- 4 諧波分析-諧波功率
PMF635A 電能質(zhì)量在線監(jiān)測(cè)裝置(單回路)21
8 錄波分析
“錄波分析”頁面主要用于配置定時(shí)錄波與觸發(fā)錄波, 終端軟件會(huì)根據(jù)設(shè)置的配置項(xiàng),在特定事件發(fā)生的時(shí)候進(jìn)行錄波,并將波形文件保存于 SD 目錄下,文件路徑為/sd0/export/record,波形文件已 IEEE 標(biāo)準(zhǔn)電力系統(tǒng)暫態(tài)數(shù)據(jù)交換通用格式COMTRADE 進(jìn)行保存。
8.1 定時(shí)錄波
導(dǎo)航菜單選擇“定時(shí)錄波”選項(xiàng)卡,支持“立即錄波”與“預(yù)約錄波”:1. 立即錄波:點(diǎn)擊“立即錄波”按鈕,設(shè)備會(huì)開始進(jìn)行錄波,錄波結(jié)束保存的comtrade
文件名會(huì)顯示于界面上,錄波時(shí)長可以在界面中進(jìn)行配置;2. 預(yù)約錄波:點(diǎn)擊“預(yù)約錄波”按鈕,設(shè)備會(huì)在設(shè)定的時(shí)間點(diǎn)到達(dá)后,自動(dòng)開始進(jìn)行錄波,錄波時(shí)長與開始錄波的時(shí)間可以在界面中進(jìn)行配置。圖 8- 2 錄波分析-定時(shí)錄波
8.2 觸發(fā)錄波
導(dǎo)航菜單選擇“觸發(fā)錄波”選項(xiàng)卡,可以配置事件觸發(fā)錄波,當(dāng)特定事件發(fā)生如穩(wěn)態(tài)告警、外部電平改變發(fā)生,設(shè)備就會(huì)開始進(jìn)行錄波:
1. 告警錄波:告警類型支持頻率上/下越限,電壓/電流負(fù)序不平衡,電壓上/下越限,電壓總畸變率越限,如果界面中已經(jīng)勾選相應(yīng)時(shí)間并保存配置,事件發(fā)生即會(huì)開始錄波;
2. 電平錄波:PMF635A 支持外部觸發(fā)錄波,當(dāng)外部電平改變且配置已關(guān)聯(lián)開入某個(gè)動(dòng)作, 設(shè)備就會(huì)開始進(jìn)行錄波。
PMF635A 電能質(zhì)量在線監(jiān)測(cè)裝置(單回路)22
圖 8- 2 錄波分析-觸發(fā)錄波
PMF635A 電能質(zhì)量在線監(jiān)測(cè)裝置(單回路)23
9 事件告警
“事件告警”頁面主要用于顯示過去發(fā)生的告警事件,告警事件分兩大類:穩(wěn)態(tài)告警和暫態(tài)告警,事件列表按降序排序,最近發(fā)生的事件排在最頂端,可以將光標(biāo)定位到列表進(jìn)行翻頁查看,同時(shí)支持按日期查詢,對(duì)過去發(fā)生的事件查看,快速正確的定位電能質(zhì)量問題。9.1 暫態(tài)告警
暫態(tài)告警事件的閥值配置可以到“參數(shù)設(shè)置”進(jìn)行更改,暫態(tài)事件類型主要有:電壓暫升、電壓暫降、電壓中斷以及沖擊電流。
當(dāng)暫態(tài)事件發(fā)生后,PMF635A 設(shè)備告警燈會(huì)進(jìn)行閃爍提示,并保存對(duì)應(yīng)的暫態(tài)事件記錄, 內(nèi)容包括暫態(tài)事件開始時(shí)間、結(jié)束時(shí)間以及暫態(tài)事件類型,幫助您第一時(shí)間分析與解決電能質(zhì)量問題。
圖 9- 1 事件告警-暫態(tài)事件
9.2 穩(wěn)態(tài)告警
穩(wěn)態(tài)告警事件的閥值配置可以到“參數(shù)設(shè)置”進(jìn)行更改,PMF635A 支持的穩(wěn)態(tài)事件類型主要有:電壓上越限、電壓下越限、電壓諧波含有率越限、電壓負(fù)序不平衡越限、電流負(fù)序不平衡越限、諧波總畸變率越限、長閃變?cè)较?、短閃變?cè)较?、頻率上越限、頻率下越限以及諧波電流有效值越限。
當(dāng)穩(wěn)態(tài)事件發(fā)生后,PMF635A 設(shè)備告警燈會(huì)進(jìn)行閃爍提示,并保存對(duì)應(yīng)的穩(wěn)態(tài)事件記錄,內(nèi)容包括事件開始/結(jié)束時(shí)間以及具體的穩(wěn)態(tài)事件內(nèi)容(事件類型、越限/恢復(fù)值、具體相位),幫助您第一時(shí)間分析與解決電能質(zhì)量問題。
PMF635A 電能質(zhì)量在線監(jiān)測(cè)裝置(單回路)24
圖 9- 2 事件告警-穩(wěn)態(tài)告警
PMF635A 電能質(zhì)量在線監(jiān)測(cè)裝置(單回路)25
10 參數(shù)設(shè)置
進(jìn)入“錄波”頁面后,可以看到頁面內(nèi)容區(qū)頂部的導(dǎo)航條有手動(dòng)錄波、定時(shí)錄波、觸發(fā)錄波和 DI 電平錄波子菜單。
“參數(shù)設(shè)置”頁面主要用于配置與查看 PMF635A 各項(xiàng)電能指標(biāo)參數(shù),包括基本參數(shù)、暫態(tài)參數(shù)、穩(wěn)態(tài)參數(shù)、諧波電流參數(shù)與接線方式,PMF635A 根據(jù)配置的參數(shù)對(duì)電能數(shù)據(jù)項(xiàng)計(jì)算以及事件判斷等。
10.1 基本參數(shù)
導(dǎo)航菜單選擇“基本參數(shù)”選項(xiàng)卡,查看與更改電能質(zhì)量的基本參數(shù),主要參數(shù)項(xiàng)有:表 10- 1 基本參數(shù)說明
設(shè)置項(xiàng)目 范圍 備注
1 次PT 1~9999.0 一次電壓/二次電壓1 次 CT 1~9999.0 一次電流/二次電流N 相PT 1~9999.0 一次電壓/二次電壓N 相 CT 1~9999.0 一次電流/二次電流標(biāo)稱電壓 0~230 單位:V
標(biāo)稱電流 0~5 單位:A
統(tǒng)計(jì)記錄周期 1/2/3/5/10 單位:分鐘
存儲(chǔ)時(shí)間周期 1/2 單位:小時(shí)
最小短路容量 0.1~9999.0 單位:MVA
外接零序 是 或者 否
電壓等級(jí)
380V、6KV、10KV、35KV、
66KV、110KV、220KV
導(dǎo)航菜單選擇“基本參數(shù)”選項(xiàng)卡,查看與更改電能質(zhì)量的基本參數(shù),主要參數(shù)項(xiàng)有:圖 10- 1 參數(shù)設(shè)置-基本參數(shù)
PMF635A 電能質(zhì)量在線監(jiān)測(cè)裝置(單回路)26
10.2 暫態(tài)參數(shù)
導(dǎo)航菜單選擇“暫態(tài)參數(shù)”選項(xiàng)卡,查看與配置暫態(tài)事件判斷閥值與記錄事件波形前后周期數(shù)。
圖 10- 2 暫態(tài)參數(shù)界面
參數(shù)說明如表 10-2 所列:
表 10- 2 暫態(tài)參數(shù)說明
設(shè)置項(xiàng)目 范圍 備注電壓暫升閥值 110.0~180.0 單位:%
電壓暫降閥值 10.0~90.0 單位:%
電壓中斷閥值 1.0~10.0 單位:%
沖擊電流 110~200 單位:%
前置周期 2~10 無
附加周期 2~50 無
10.3 穩(wěn)態(tài)參數(shù)
導(dǎo)航菜單選擇“穩(wěn)態(tài)參數(shù)”選項(xiàng)卡,查看與配置穩(wěn)態(tài)事件判斷的閥值。
PMF635A 電能質(zhì)量在線監(jiān)測(cè)裝置(單回路)27
圖 10- 3 參數(shù)設(shè)置-穩(wěn)態(tài)參數(shù)
參數(shù)說明如表 10-3 所列:
表 10- 3 穩(wěn)態(tài)參數(shù)說明
設(shè)置項(xiàng)目 范圍 備注電壓總畸變率越限值 0.01~30.0 單位:%
電壓奇次諧波含有率 0.01~10.0 單位:%
電壓偶次諧波含有率 0.01~10.0 單位:%
電壓負(fù)序不平衡越限值 0.01~10.0 單位:%
電流負(fù)序不平衡越限值 0.01~10.0 單位:%
短閃變 0.0~30.0 無長閃變 0.0~30.0 無電壓上偏差 101~110 單位:%
電壓下偏差 90~99 單位:%
頻率上越限 50.2~50.5 單位:Hz頻率下越限 49.5~49.8 單位:Hz 10.4 諧波電流
導(dǎo)航菜單選擇“穩(wěn)態(tài)參數(shù)”選項(xiàng)卡,查看與配置諧波電流允許值。
PMF635A 電能質(zhì)量在線監(jiān)測(cè)裝置(單回路)28
圖 10- 4 參數(shù)設(shè)置-諧波電流
操作說明如下:
◆ 各項(xiàng)均表示閥值,需輸入有效數(shù)據(jù);電壓等級(jí)的不同,諧波電流的標(biāo)準(zhǔn)閥值也不一樣,當(dāng)修改電壓等級(jí)時(shí),諧波電流會(huì)變換到相應(yīng)的標(biāo)準(zhǔn)閥值;
◆ 點(diǎn)擊“保存”按鈕,進(jìn)行保存。
10.5 接線方式
導(dǎo)航菜單選擇“接線方式”選項(xiàng)卡,配置當(dāng)前設(shè)備的接線模式,本裝置共支持二大類接線模式:“三相三線制”、“三相四線制”。
三相三線星型接法:
圖 10- 5 參數(shù)設(shè)置-三相三線星型接法
三相三線三角型接法:
PMF635A 電能質(zhì)量在線監(jiān)測(cè)裝置(單回路)29
圖 10- 6 參數(shù)設(shè)置-三相三線三角型接法
三相三線 2CT 接法:
圖 10- 7 參數(shù)設(shè)置-三相三線 2CT 接法
三相四線星型接法:
PMF635A 電能質(zhì)量在線監(jiān)測(cè)裝置(單回路)30
圖 10- 8 參數(shù)設(shè)置-三相四線星型接法
PMF635A 電能質(zhì)量在線監(jiān)測(cè)裝置(單回路)31
11 系統(tǒng)設(shè)置
“系統(tǒng)設(shè)置”頁面顯示與配置當(dāng)前設(shè)備系統(tǒng)參數(shù),主要系統(tǒng)參數(shù)包括網(wǎng)絡(luò)、協(xié)議、校時(shí)、繼電器以及設(shè)備密碼,通過系統(tǒng)設(shè)置可以方便的管理設(shè)備。
11.1 系統(tǒng)信息
導(dǎo)航菜單選擇“系統(tǒng)信息”選項(xiàng)卡,可以查看系統(tǒng)的各種版本信息,包括:軟件版本、硬件版本、DSP 版本以及 FPGA 版本。
圖 11- 1 系統(tǒng)設(shè)置-系統(tǒng)信息
11.2 網(wǎng)絡(luò)設(shè)置
導(dǎo)航菜單選擇“網(wǎng)絡(luò)設(shè)置”選項(xiàng)卡,配置網(wǎng)絡(luò)地址、子網(wǎng)掩碼和默認(rèn)網(wǎng)關(guān),PMF635A設(shè)備具有檢測(cè) IP 沖突功能,當(dāng)設(shè)置的 IP 地址與局域網(wǎng)中某臺(tái)主機(jī)或者設(shè)備的IP 沖突的時(shí)候, 界面會(huì)做相應(yīng)的提示。
圖 11- 2 系統(tǒng)設(shè)置-網(wǎng)絡(luò)設(shè)置
PMF635A 電能質(zhì)量在線監(jiān)測(cè)裝置(單回路)32
11.3 協(xié)議設(shè)置
導(dǎo)航菜單選擇“協(xié)議設(shè)置”選項(xiàng)卡,對(duì)系統(tǒng)的通信協(xié)議進(jìn)行設(shè)置,系統(tǒng)支持的協(xié)議有IEC-103、Modbus-485 以及 Modbus-TCP。
圖 11- 3 系統(tǒng)設(shè)置-協(xié)議設(shè)置
操作說明如下:
◆ 選擇協(xié)議類型選擇框,更改協(xié)議類型選擇某一種協(xié)議;
◆ 根據(jù)不同的協(xié)議對(duì)配置項(xiàng)進(jìn)行設(shè)置;
◆ 點(diǎn)擊“保存”按鈕,若修改成功,則更換當(dāng)前系統(tǒng)的協(xié)議配置信息。11.4 校時(shí)設(shè)置
導(dǎo)航菜單選擇“校時(shí)設(shè)置”選項(xiàng)卡,對(duì)系統(tǒng)的校時(shí)方式進(jìn)行配置,主要的校時(shí)方式有手動(dòng)校時(shí)、SNTP 校時(shí)、B 碼校時(shí)和 PPS 校時(shí)。
圖 11- 4 系統(tǒng)設(shè)置-校時(shí)設(shè)置
操作說明如下:
◆ 光標(biāo)定位到協(xié)議類型選擇框,選擇想要的校時(shí)方式;
◆ 配置所選擇的校時(shí)方式參數(shù);
PMF635A 電能質(zhì)量在線監(jiān)測(cè)裝置(單回路)33
◆ 點(diǎn)擊保存按鈕,在彈出界面中輸入密碼;
◆ 除手動(dòng)校時(shí)外,其他校時(shí)方式如果校時(shí)成功,界面會(huì)做相應(yīng)提示,以便知道設(shè)備當(dāng)前校時(shí)狀態(tài)。
11.5 繼電器
導(dǎo)航菜單選擇“校時(shí)設(shè)置”選項(xiàng)卡,可以對(duì)系統(tǒng)繼電器進(jìn)行配置,PMF635A 設(shè)備有兩個(gè)繼電器,通過將光標(biāo)定位選擇繼電器選擇框切換繼電器 1/2,對(duì)繼電器狀態(tài)查看與配置,外部通過檢查繼電器狀態(tài)了解當(dāng)前設(shè)備運(yùn)行情況。
繼電器 1:用于關(guān)聯(lián)設(shè)備開/關(guān)機(jī)狀態(tài),設(shè)備開機(jī)狀態(tài)與繼電器狀態(tài)對(duì)應(yīng)情況。表 11- 1 繼電器 1 關(guān)聯(lián)設(shè)備狀態(tài)對(duì)照表
設(shè)備狀態(tài) 繼電器狀態(tài)
開機(jī) 斷開
關(guān)機(jī) 閉合
圖 11- 5 系統(tǒng)設(shè)置-繼電器 1
繼電器 2:用于關(guān)聯(lián)設(shè)備部分穩(wěn)態(tài)告警事件與暫態(tài)事件,當(dāng)勾選的事件發(fā)生時(shí)繼電器閉合,事件結(jié)束繼電器斷開。
PMF635A 電能質(zhì)量在線監(jiān)測(cè)裝置(單回路)34
圖 11- 6 系統(tǒng)設(shè)置-繼電器 2
11.6 高級(jí)設(shè)置
導(dǎo)航菜單選擇“高級(jí)設(shè)置”選項(xiàng)卡,可對(duì)系統(tǒng)語言以及系統(tǒng)密碼進(jìn)行設(shè)置,默認(rèn)進(jìn)入頁面為語言設(shè)置,當(dāng)前系統(tǒng)支持中文及英文兩種語言,設(shè)置完成后保存即可應(yīng)用。圖 11- 7 系統(tǒng)設(shè)置-語言設(shè)置
將“其他參數(shù)”選項(xiàng)框切換至“密碼”,可以對(duì)系統(tǒng)密碼進(jìn)行設(shè)置,系統(tǒng)密碼用于防止非工作人員更改設(shè)備配置,在更改配置進(jìn)行保存的時(shí)候,設(shè)備會(huì)提示輸入密碼。密碼驗(yàn)證有超時(shí)機(jī)制:輸入密碼后在一定時(shí)間內(nèi)不用輸入密碼,以便用戶更快操作,密碼超時(shí)如果再次更改配置需要重新驗(yàn)證密碼。
PMF635A 電能質(zhì)量在線監(jiān)測(cè)裝置(單回路)35
圖 11- 8 系統(tǒng)設(shè)置-密碼設(shè)置
將“其他參數(shù)”選項(xiàng)框切換至“關(guān)閉屏幕”,可對(duì)屏幕關(guān)閉時(shí)間進(jìn)行設(shè)置,出廠默認(rèn)關(guān)閉屏幕時(shí)間為 10 分鐘,可選項(xiàng)包括從不、十分鐘、30 分鐘、60 分鐘。設(shè)置完成后保存即可應(yīng)用。
圖 11- 9 系統(tǒng)設(shè)置-關(guān)閉屏幕設(shè)置
PMF635A 電能質(zhì)量在線監(jiān)測(cè)裝置(單回路)36
12 免責(zé)申明
本著為用戶提供更好服務(wù)的原則,許昌智能繼電器股份有限公司(下稱“許昌智能”)在本手冊(cè)中將盡可能地為用戶呈現(xiàn)詳實(shí)、準(zhǔn)確的產(chǎn)品信息。但介于本手冊(cè)的內(nèi)容具有一定的時(shí)效性,許昌智能不能完全保證該文檔在任何時(shí)段的時(shí)效性與適用性。許昌智能有權(quán)在沒有通知的情況下對(duì)本手冊(cè)上的內(nèi)容進(jìn)行更新,恕不另行通知。為了得到最新版本的信息,請(qǐng)尊敬的用戶定時(shí)訪問許昌智能官方網(wǎng)站或者與許昌智能工作人員聯(lián)系。感謝您的包容與支持!
許昌智能繼電器股份有限公司地址:河南省許昌市中原電氣谷-許昌智能科技大廈郵編:461000
訂貨咨詢:0374-3211522
訂貨傳真:0374-3212359
服務(wù)熱線:400-0374-655
E-mail:znsc@xjpmf.com